Alliance Laundry Systems SWD441C Manual De Instalación página 26

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
2. Remove the three screws holding the three wires
to the terminal block terminals. Save these
screws. Loosen the strain relief screw and pull the
cord or wires out through the rear of the dryer.
Figure 32
3. Remove ground screw and save for use in step 5.
Remove wire and use in step 6.
1
Ground Screw
Figure 33
4. Use a strain relief and insert end of power cord
through power supply hole.
1
1
Power Cord Ground Wire
Figure 34
24
D696I
1
D697I
D697I
D698I
D698I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5. Attach power cord ground (green) wire to rear
bulkhead using ground screw removed in step 3.
6. Use the three screws from the envelope located in
the cylinder to attach the remaining power cord
wires to the terminal block as follows:
a. Red wire to "L1" terminal.
b. Black wire to "L2" terminal.
c. White wire to Neutral terminal.
1
7
6
5
1
"L1" Terminal
2
White
3
"L2" Terminal
4
Black
5
Green
6
Red
7
Neutral Terminal
Figure 35
NOTE: When installing the white wire, loop the
free eyelet end of the ground wire (removed in
step 3) and attach along with the white wire to the
neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
8. Check the continuity of the ground connection
before plugging the cord into the outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of cabinet.
9. Reinstall access cover and screw.
2
3
4
DRY522N
801504