Electrical Requirements

Gas Dryer

(120 Volt, 60 Hertz, with 3-Prong Grounding Plug)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1,
and such local regulations as might apply. It
is the customer's responsibility to have the
wiring and fuses checked by a qualified
electrician to make sure the laundry room
has adequate electrical power to operate the
dryer.
The dryer is designed to be operated on a
G
separate branch, polarized, three-wire, effectively
grounded, 120 Volt, 60 Hertz, AC (alternating
current) circuit protected by a 15 Ampere fuse,
equivalent fusetron or circuit breaker.
The three-prong grounding plug on the power
G
cord should be plugged directly into a polarized
three-slot effectively grounded receptacle rated
120 Volts AC (alternating current) 15 Amps.
Refer to Figure 37 to determine correct polarity
of the wall receptacle.
WARNING
This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged
directly into a properly grounded three-
prong receptacle. Do not cut or remove the
grounding prong from this plug.
801504
W035
W036
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: A qualified electrician should check the
polarity of the wall receptacles. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.
DO NOT OPERATE OTHER APPLIANCES
G
ON THE SAME CIRCUIT WHEN THIS
APPLIANCE IS OPERATING. DO NOT
OVERLOAD CIRCUITS!
DO NOT operate both a washer and gas dryer on
G
the same circuit. Use separately fused 15 Amp
circuits.
WARNING
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer to the electrical
power source.
DO NOT OVERLOAD
CIRCUITS
DO NOT USE AN
ADAPTER
DO NOT USE AN
EXTENSION CORD
Figure 36
Installation
W037
D009I
25