•
To be installed and operated only by an adult. Not
to be used by children.
•
Never install in areas where swimming is allowed
or where people enter the water.
•
Never use in a swimming pool.
•
Do not use this equipment for intentional weed
removal, sediment removal or dredging.
•
Follow all local and national electrical wiring rules
for the electrical circuit feeding this equipment.
Failure to comply may result in injury.
•
All equipment must be powered from an RCD
(residual current device) or GFCI (ground fault
circuit interrupter) protected circuit.
•
Do not modify any mounting hardware or guard-
ing provided with this equipment. All guarding
purchased with a unit must be installed.
•
This equipment is intended to operate without
interaction from personnel. Never to be manipu-
lated, moved, maintained, or adjusted while in
operation. Damage or injury could result.
•
The general public must be made aware of the in-
stallation and warned of the installation to prevent
misuse or interference with the equipment.
•
This equipment is intended to be used in water
only. The equipment should only be operated
out of water if required to troubleshoot operation
and during initial startup of the equipment. The
instructions provide detailed warnings and instruc-
tions for such activities and should only be per-
formed by a trained person.
Unit Specs
Model
Voltage
range
3.1EVX
208-240
8400EJ
208-240
3.1EJ
208-240
3.3EVX
190
2.3EJ
190
3.3EJ
190
5.3EJ
190
3.3EHVX
380
2.3EHJ
380
3.3EHJ
380
Operating
lock rotor
amps
amps
12.5@220V 60@220V
9.5@220V
40@220V
13.2@220V 60@220V
9.6
69
6.4
41
10
69
15.2
98
4.8
34
3.3
21
5
34
Model
Voltage
range
5.3EHJ
380
Utility requirements:
The Electrical circuit must be provided to supply suf-
fi cient voltage and amperage to the unit. These ratings
are listed in the above table (unit specs). This circuit
must also include a disconnect means and short circuit
protection.
Quick Disconnect Installation
Important – Read Carefully Before Installation
Before using the connector, it is important that these
instructions are carefully read and understood to
ensure the connector system is completely water tight
and electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRI-
CIAN.
The socket (female) insert of the connector must be
the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or
electrical device. On 50Hz units, the pin (male) insert
of the connector is installed at the factory. To ensure
effi cient sealing, use only smooth circular cable.
Pin Insert (Installed on Stub Cord)
Main Body
Pin Insert
Socket Insert (User Installed)
Socket insert
Main Body
Note:
White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.
Operating
lock rotor
amps
amps
7.7
49
Gland
Gland Nut
Gland
Gland Nut
3