Display message
BL
Block due to water failure
Block due to low line voltage
LP
(less than 180VAC)
Block due to high internal
HP
power supply voltage
Block due to overheating of
OT
final power stages
(TE > 100°C)
Block due to overheating of
OB
printed circuit
(BT> 120°C)
Block due to current
OC
overload on electric pump
motor
Block due to current
OF
overload on final stages of
output
Table 30: Auto-reset of blocks
Pumpland.ru
ENGLISH
Automatic reset of error conditions
Description
- One attempt every 10 minutes for a total of 6
attempts
- One attempt every hour for a total of 24 attempts
- One attempt every 24 hours for a total of 30 attempts
- Reset when voltage on the terminal returns to above
200VAC
- Reset when voltage returns to a specified value
- Reset when temperature of final power stages falls
below 85°C
- Reset when temperature of printed circuit falls below
100°C
-
-
-
-
-
-
106
Automatic reset sequence
An attempt every 10 minutes for a total of 6
attempts
An attempt every hour for a total of 24 attempts
An attempt every 24 hours for a total of 30
attempts
An attempt every 10 minutes for a total of 6
attempts
An attempt every hour for a total of 24 attempts
- An attempt every 24 hours for a total of 30
attempts