Checking Drainage - Sharp AY-X36RU Manual De Instalación

Ocultar thumbs Ver también para AY-X36RU:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3
SETTING UP THE INDOOR UNIT
Piping route
For directions 1, 2 and 5, cut out the specific zone
without leaving any sharp edge.
(Keep the cut-out plate for possible future use.)
Mounting the indoor unit
For right side piping
(1) Reverse the positions of the drain hose and
drain cap. Refer to "Exchange the drain
hose".
(2) Pass the pipes, connecting cable and the drain
hose through the piping hole.
(3) Hook the unit onto the mounting plate.
(4) Push the unit and apply the bottom hooks to
the mounting plate's support.
(5) Pull the bottom of the unit to check that the unit
is fixed in place.
For left side piping
(1) Connect the pipes and wrap tape around the
insulation of the piping joints tightly not to be-
come thick.
(2) Bind the pipes and connecting cable with tape.
(3) Set the them along the back of the unit.
(4) Pass the pipes, connecting cable and the drain
hose through the piping hole.
(5) Hook the unit onto the mounting plate.
(6) Push the unit and apply the bottom hooks to
the mounting plate's support.
(7) Pull the bottom of the unit to check that the unit
is fixed in place.
Notes:
• Bend the pipes carefully as not to damage them.
• Lay the drain hose below the pipes.
4 CONNECTING THE DRAIN HOSE TO THE INDOOR UNIT
Connecting the drain hose
(1) Connect a drain hose.
(2) Tape over the connecting part.
ø16 mm
Drain hose
(Commercially available)
Checking drainage
(1) Open the open panel.
(2) Remove the air filters.
(3) Pour some water into the drain pan.
(4) Check the water drains smoothly.
AYX36RU_IM_3_lang.indb 3
Plate
Drain cap
Drain hose
MOUNTING PLATE
Taping
Hook
MOUNTING PLATE
Pipes
Drain Hose
Tape
Notes:
• Be sure to lay the drain hose downward for smooth drainflow.
• Be careful not to allow the drain hose to rise, form a trap or leave
its end in water, as shown below.
• Coil thermal insulation around a drain hose extension, if running in
the room.
GB-3
Plate
Cut the plate along notch.
Plate
Exchange the drain hose
(1) Unhook and pull out
the drain hose.
Drain hose
(2) Pull out the drain cap.
Drain cap
(3) Reconnect the drain hose and the drain
cap.
• Fully insert the drain hose until it stops
and hook on the projection.
• Insert a hexagon wrench into the drain
cap, and press it fully.
Drain hose
Hexagon wrench
Caution:
After replacing, make sure that both the
drain hose and drain cap are firmly inserted.
No trap
Not to rise.
allowed.
Not running wavy.
No trap allowed.
Drain cap
Not left in water.
2014-09-12 07:59:33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ae-x36ru