Check code
Outdoor unit 7-segment display
Wired remote
controller display
L02
L02
L03
L04
L04
L05
L06
L06
No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L17
L17
L18
L18
L20
L28
L28
L29
L29
*1 Inverter quantity information
L30
L30
Detected indoor unit address
L31
P01
P03
P03
01: Comp. 1 side
P04
P04
02: Comp. 2 side
03: Comp. 3 side
00:
01: Comp. 1 side
P05
P05
02: Comp. 2 side
03: Comp. 3 side
01: Comp. 1 side
02: Comp. 2 side
P07
P07
03: Comp. 3 side
-----------------------------------------------------------------------------------------
04: Heat sink
P10
P10
Detected indoor unit address
P11
P11
P12
P13
P13
01: TS condition
P15
P15
02: TD condition
P17
P17
P19
P19
Detected outdoor unit number
P20
P20
#0: Element short circuit
#E: Vdc voltage trouble
#1: Position detection circuit trouble
#2: Input current sensor trouble
#3: Motor lock trouble
P22
P22
#C: Sensor temperature trouble (No TH sensor)
#4: Motor current trouble
#D: Sensor short circuit/release trouble (No TH sensor)
#5: Synchronization/step-out trouble
*Put in Fan Inverter No. in [#] mark.
49-EN
1115652706_01_EN.indd 25
1115652706_01_EN.indd 25
Wireless remote controller
Sensor block display of receiving unit
Auxiliary code
Operation
– 25 –
Timer
Ready
Flash
SIM
Model mismatch of indoor and outdoor unit
SIM
Indoor unit centre unit duplicated
SIM
Outdoor unit line address duplicated
SIM
Duplicated indoor units with priority (Displayed in indoor unit with priority)
Duplicated indoor units with priority
SIM
(Displayed in unit other than indoor unit with priority)
SIM
Group line in individual indoor unit
SIM
Indoor unit group/Address unset
SIM
Indoor unit capacity unset
SIM
Outdoor unit capacity unset
SIM
Outdoor unit type mismatch trouble
SIM
Flow selector unit trouble
SIM
Duplicated central control addresses
SIM
Too many outdoor units connected
SIM
No. of inverter trouble
SIM
Indoor unit outside interlock
Extended I/C trouble
ALT
Indoor fan motor trouble
ALT
Discharge temp. TD1 trouble
ALT
High-pressure SW system operation
Phase missing detection/Power failure detection
Inverter DC voltage trouble (comp.)
ALT
Inverter DC voltage trouble (comp.)
Inverter DC voltage trouble (comp.)
Heat sink overheat trouble
ALT
-----------------------------------------------------------------------------------------------------
Heat sink dew condensation trouble
ALT
Indoor unit overflow trouble
ALT
Outdoor heat exchanger freezing trouble
ALT
Indoor unit fan motor trouble
ALT
Outdoor liquid back detection trouble
ALT
Gas leak detection
ALT
Discharge temp. TD2 trouble
ALT
4-way valve inverse trouble
ALT
High-pressure protective operation
ALT
Outdoor unit fan inverter trouble
Check code name
Judging device
Indoor unit
Indoor unit
Indoor unit, I/F
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Inverter
Inverter, I/F
Indoor unit
Indoor unit
Inverter
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
I/F
50-EN
10/8/20 8:11 PM
10/8/20 8:11 PM