back; INC key is used to plus 1 at one time to the parameter needed setup; and
DEC key is used to minus 1 at a time to the parameter required setup
2.
Entry and Exit Menu Setup
1. Enter menu
Press set key, after hearing a sound "du", loosen from SET key. At this time, The
word "poo" is displayed, which means that it's in status of menu setup. And at this
time INC key and DEC key can be choose to setup
2. Function number
Press INC key for function number plus one , and press DEC
key for function number minus one; there are 15 kinds of functions as below:
POO: Exit from menu setting, when POO appears, press SET Key to back.
PO1: The running direction when power on,=000 means forward rotating, and
• 001: means reversal reverse
P02: The longest time of barrier's operation, its measurement is 0.1sec, so when
we set time 60, the time of barrier closing is 6 seconds. When the barrier has not
closed in 6 sec, it will automatically stop. (System default is 60)
P03: The passing time, measurement is second. Number 10 means 10 seconds,
turnstile close of pedestrian didn't pass turnstile in 10S (System default is 10)
P04: Working mode (System default is 000) =000 bi-direction use(swipe card)
• 001: swipe card for entry but exit freely =002 swipe card for exit but entry freely
• 003: entry and exit are freely
• 004: entry only (single direction) =005 exit only (single direction)
P05: The speed of barrier gate opening for entry, system default is 10.
P06: The speed of barrier gate closing after entry, system default is 10.
P07: The speed of barrier gate opening for exit, system default is 10
P08: The speed of barrier gate close after exit, system default is 10.
P09: The pedestrians pass through the barrier gate in the pre-set time will be re-
garded as one person.(system default is 10)
P10: Entry counter reset: when P10 appear, press SET , it display C-L, press INC ,
entry counter reset
P11: Exit counter reset:, when P11 appear, press SET , it display C-R, press INC ,exit
counter reset.
P12: Memory function setup (system default is 000)
• 000: entry and exit with memory,
• 001: entry without memory,exit with memory
• 002: entry with memory,exit without memory
• 003: entry and exit without memory