RAGGIO C
ECO mode
The ECO mode minimizes energy consumption, but it may take longer for the DHW to reach the
required temperature.
With the ECO function disabled, the temperature of the water inside the boiler is maintained, en-
suring the availability of hot water at the faucet.
Restoring system hydraulic pressure
The boiler provides for various ways of restoring the hydraulic system. pressure. Manual, always
available, or semiautomatic or automatic depending on the parameter value P62.
"Pressure control" screen
To access the pressure control screen, simply touch the pressure value (detail [4] - fig. 8) on the
main screen.
Description of "Pressure control" screen
45.5°
ON
Legend fig. 8
Back to main screen
1
Pressure status indicator (see attached
2
table)
Boiler operating pressure zone
3
4a Pressure zone too high (boiler blocked)
Current pressure indicator
5
Current pressure value
6
Icon
Fault code
F40
RED
F21
YELLOW
NONE
GREEN
F20
YELLOW
F37
RED
EN
Jul 29 2020 14:36
Connected
0.3
BAR
[4]
21.0°
OFF
ON
OFF
fig. 8- Pressure control
Description
Pressure too high for boiler operation
Pressure higher than nominal value
The boiler works at limited output
Pressure in optimal range
Pressure lower than nominal value
The boiler continues to work normally
Pressure too low for boiler operation
cod. 3541V280 - Rev. 00 - 03/2021
Jul 29 2020
14:36
Connected
[ 2 ]
Low pressure
Press restore to bring the pressure back to the optimal value
[ 9 ]
0.4
[ 3 ]
[ 5 ]
[ 6 ]
[ 7 ]
0.3
0
BAR
[ 8 ]
RESTORE
Pressure zone too low, boiler operation
7
inhibited
Pressure reset button (enabled in se-
8
miautomatic mode)
Optimal pressure indicator
9
[ 1 ]
1.6
[ 4a ]
2.5
169