OFFSET and SLOPE 100% calibration
With this procedure it is possible to do (if necessary) a fine setting on the automatic calibration that
the boiler performs. With this setting it is possible to raise or lower the entire combustion curve
and change the slope.
Procedure
• Put the boiler (preferably) in heating mode or else in DHW mode.
• Access the [
• Access the [
• Enter the password "1234" and confirm [
• Select [Combustion Control]
• Select the parameter [15/100% calibration]
• Type "3"
• Press [OK] to confirm
• The main screen will appear with the flashing flame icon and the message [Calibration in pro-
gress].
• At the end of the calibration procedure, the display will show the screen relevant to the para-
meter Sc12*
Modify the parameter with the + and – buttons.
After finding the correct operating point, press [OK].
• The main screen will appear again with the flashing flame icon and the message [Calibration
in progress].
• At the end of the second calibration procedure, the display will show the screen relevant to the
parameter Sc13**.
Modify the parameter with the + and – buttons.
After finding the correct operating point, press [OK].
• The main screen will appear.
The message [Calibration in progress] disappears
The flame stops flashing and goes off or remains steady, depending on the boiler status.
* SC12 adjusts the CO
lue the CO
decreases; by decreasing the parameter value the CO
2
** SC13 adjusts the CO
ses; by decreasing the parameter value the CO
Loading parameters with "BCC KEY"
The "BCC KEY" device allows the updating of combustion parameters for boiler type.
It is used in case of replacement of the PCB of some boiler models.
To use the "BCC KEY", refer to the instructions contained in the kit.
TEST mode activation
• Access the [
• Access the [
• Enter the password "1234" and confirm [
• Press [Test Mode]. The display shows the operating information.
• Burner power can be increased or decreased by touching [+] and [-].
• Wait about 1 minute for the values to stabilize
The [Test Mode] remains active as long as the user remains on the corresponding screen. It is
automatically deactivated on exiting the screen or after 20 minutes of user inactivity.
Press [
] to return to the [
Maximum heating power adjustment
To adjust the maximum heating power:
• Access the [
• Access the [
• Enter the password "1234" and confirm [
EN
User Menu]
Service Menu] and press [confirm]
simultaneously at max. and min. power. By increasing the parameter va-
2
at minimum power. By increasing the parameter value the CO
2
User Menu]
Service Menu] and press [confirm]
Service Menu] or [
User Menu]
Service Menu] and press [confirm]
cod. 3541V280 - Rev. 00 - 03/2021
]
increases.
2
increases.
2
]
] to return to the main screen.
]
decrea-
2
189

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido