Legacy Levelwind Serie Guía De Componentes Y Servicio Técnico

Ocultar thumbs Ver también para Levelwind Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Please read and follow instructions
carefully; otherwise, warranty may be void.
Mounting Options:
CAUTION: Maximum installation height is 15 ft. (4.5 meters) above ground. Maximum weight of hose end tools is 4 lb. ( 2 kg). Maximum working
pressure is 350 PSI. Do not stand or step on top of reel!
M M o o u u n n t t i i n n g g t t o o w w a a l l l l
Positioned up to 5 ft. (1.8 m) high.
Use standard Replacement Part
L8300-W Wall /Overhead bracket
H H i i g g h h W W a a l l l l M M o o u u n n t t i i n n g g
Mount reel between 10 ft. and 15 ft.
high on wall. Use optional Bench / High
Wall mounting bracket Model L8300-B
Installation:
LEVELWIND retractable hose reels are designed for minimum assembly.
1) Place bracket on a flat mounting surface. With a pencil trace bracket
back holes onto surface. Use a leveling device to ensure that the
bracket will be level once fastened. Fasten brackets to surface with
screws ( screws are not included ).
2) Remove Bracket Rod (A) from Bracket (B) ( SEE FIGURE 1 )
3) Place reel into bracket making sure the reel hole is aligned with
bracket end holes.
4) Insert Bracket Rod through the aligned holes of Reel and Bracket.
5) Connect female end of lead-in hose to inlet connection on reel.
Connect male end to air or water source ( SEE FIGURE 2 ).
Operating Instructions:
LEVELWIND retractable hose reels can operate in FREERUN or can be latched every 3 ft. by switching to the LATCHING ZONE. Simply turn the mode
switch to desired position! ( SEE FIGURE 3 )
THE "LATCHING ZONE": LEVELWIND reels have a single latching zone. The reel can be latched for every drum revolution
approx. 3 feet of hose). There are audible clicking sounds as the spring loaded latch passes over the latching zone. The latching
zone flips the latch so that the latch goes into or by-passes the latching position. Pulling hose straight out off the reel "flips the
latch" so it can go into the latching position. Retracting the hose into the reel keeps the latch "flipped" so that the latch by-
passes the latching position.
LATCHING - Pull out the desired length of hose. As you are pulling out hose from the reel, listen for a "click". STOP!
Don't pull any further! If you keep pulling out hose (more than 14") after hearing the "click", you will have pulled past the
latching zone. Now, allow the hose to go back into the reel (less than 14") and the latch will drop into the latching position. The reel is now
latched!
RETRACTING - Assuming the latch is engaged in the latching position, pull out hose until you hear a "click" (approx. 14"). STOP! Don't
pull any further! If you pull out more than 3 ft. of hose after hearing the " click", you will have gone a full drum revolution and back into the
latching zone where the reel will once again be latched. Now, allow the hose to retract back into the reel. The hose reel will continue retracting
hose until it is fully retracted. If you decide to re-latch the reel while you are still retracting hose, simply listen for a click.
STOP! Slowly pull out hose until you hear a second click. STOP! Don't pull any further. Now, slowly allow the hose back
into the reel (less than 14") and the latch will drop into the latching position. The reel is now latched.
FREERUN MODE: The hose does not latch in this mode. Hose will automatically retract back into reel. The Hose stopper
position may be adjusted to desired length for application (SEE FIGURE 4) CAUTION! Do not release the end of the hose
when rewinding as personal injury or damage could result!
Retractable Air & Water Hose Reels
Parts and Technical Service Guide
TM
Carretes retráctiles para mangueras de aire y de agua
Dévidoirs de tuyau d'air et d'eau rétractable
Model L8305
Page 1
L L e e v v e e l l w w i i n n d d
Model L8305-EU
Model L8306
Model L8335
Model L8335-EU
M M o o u u n n t t i i n n g g o o v v e e r r h h e e a a d d
Up to 15 ft. (4.5 m) from floor. Use
standard Replacement Part L8300-W Wall /
overhead bracket.
M M o o u u n n t t i i n n g g t t o o a a b b e e n n c c h h
Use optional Bench / High Wall mounting
bracket model L8300-B
Fig. 1
Fig. 2
A
Bracket
Male end to source
Rod
B
Lead-in Hose
Bracket
INS8306-0103
guía de componentes y servicio técnico
guide de pièces et de service technique
T T M M
S S e e r r i i e e s s
Model L8306-EU
Model L8310
Model L8310-EU
Model L8346
Model L8347
Model L8349
Reel Inlet
Female end to reel inlet
Fig. 3
Fig. 4
Hose Stopper

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Legacy Levelwind Serie

  • Página 1 INS8306-0103 Retractable Air & Water Hose Reels Parts and Technical Service Guide Carretes retráctiles para mangueras de aire y de agua guía de componentes y servicio técnico Dévidoirs de tuyau d'air et d'eau rétractable guide de pièces et de service technique L L e e v v e e l l w w i i n n d d T T M M S S e e r r i i e e s s...
  • Página 2: Maintenance Procedures

    Fig. 5a Fig. 6 SEVEN POSITION LOCKING BRACE Fig. 5b LEVELWIND retractable hose reels can swing freely on bracket or can be locked in one of seven positions, allowing for specific mounting requirements. S S t t a a n n d d a a r r d d b b r r a a c c k k e e t t 1) Remove bracket rod from reel.
  • Página 3: Technical Assistance

    5) Pull swivel assembly firmly from hose spool Fig. 13 Fig. 14 ( SEE FIGURE 13 and 14 ). 6) Unscrew Hose Clamp and pull hose off hose barb on swivel. Swivel Body (SEE FIGURE 15) 7) Pull remaining length of hose out reel opening located at the reel front.
  • Página 4: Repair Parts

    Repair Parts corrosive materials, or to equipment repaired or altered by anyone not authorized by LEGACY to repair and alter equipment. No allowance will be granted for any repairs or alterations made R R e e f f .
  • Página 5: Opciones Para Su Instalación

    INS8306-0103 Carretes retráctiles para mangueras de aire y de agua guía de componentes y servicio técnico L L e e v v e e l l w w i i n n d d T T M M S S e e r r i i e e s s Por favor lea y siga cuidadosamente Modelo L8305 Modelo L8305-EU Modelo L8306 Modelo L8306-EU Modelo L8310 Modelo L8310-EU...
  • Página 6 PUNTAL DE BLOQUEO EN SIETE POSICIONES Ilustración 5a Ilustración 5b Ilustración 6 Los carretes retráctiles LEVELWIND podrán desplazarse hacia los lados libremente sobre el portacarrete, o podrán bloquearse en una de sus siete posiciones, permitiéndole ajustarse a las necesidades de una instalación específica.
  • Página 7: Mecanismo Nivelador De La Manguera

    5) Tire firmemente del ensamble con rótula y extraiga el carrete de la manguera Ilustración Ilustración (VER ILUSTRACIÓN 13 y 14). 6) Destornille la abrazadera de la manguera y extraiga la espiga de la manguera en el columpio. (VER ILUSTRACIÓN 15) Ensamble con rótula 7) Tire de la longitud restante de la manguera hacia fuera de las aberturas del carrete en la parte del frente.
  • Página 8 (2) a partir de la fecha de adquisición, y bajo condiciones normales de uso, que este equipo no tiene ningún defecto en sus materiales y mano de obra. La única obligación de LEGACY según esta garantía se limita a substituir o reparar, sin costo alguno, cualquier equipo que se haya comprobado estar defectuoso bajo condiciones normales de uso según las...
  • Página 9: Options De Montage

    INS8306-0103 Dévidoirs de tuyau d'air et d'eau rétractable guide de pièces et de service technique L L e e v v e e l l w w i i n n d d S S e e r r i i e e s s T T M M Veuillez lire et suivre attentivement Modèle L8305 Modèle L8305-EU Modèle L8306...
  • Página 10 BRIDE DE VERROUILLAGE À SEPT POSITIONS Fig. 5a Fig. 6 Fig. 5b Les dévidoirs de tuyau rétractable LEVELWIND peuvent pivoter librement sur leur support ou peuvent être verrouillés sur l'une de sept positions pour répondre à des besoins de montage particuliers. S S U U P P P P O O R R T T S S T T A A N N D D A A R R D D 1) Retirer la tige du support du dévidoir.
  • Página 11 5) Tirer l'ensemble de pivot fermement hors de la bobine de tuyau. Fig. 13 Fig. 14 (VOIR FIGURES 13 et 14) 6) Dévisser la bride de tuyau et tirer le tuyau hors de la barbe de tuyau sur le pivot. (VOIR FIGURE 15) Corps de pivot 7) Tirer la longueur restante de tuyau hors de l'ouverture du dévidoir située dans la partie avant du dévidoir.
  • Página 12 2 (deux) ans à partir de la date d'achat. En vertu de la présente garantie, la seule obligation de la société LEGACY se limite à remplacer ou à réparer gratuitement le matériel se révélant défectueux à la suite d'une utilisation normale, effectuée dans des conditions normales et conformément aux recommandations de la société...

Tabla de contenido