Keypad
LED screen
The error LED flashes.
The product does not start.
The error LED comes on with red
light.
Battery
LED display
The green LED flashes.
The error LED flashes.
The error LED is on.
Battery charger
Problem
Red error LED flashes.
Red error LED comes on.
Transportation and storage
•
The supplied Li-ion batteries obey the Dangerous
Goods Legislation requirements.
•
Obey the special requirement on package and labels
for commercial transportation, including by third
parties and forwarding agents.
1637 - 003 - 06.04.2021
Troubleshooting
Possible faults
Overload
There is dirt in the battery connec-
tors.
It is necessary to do servicing on the
product
Possible faults
Low battery voltage.
Temperature deviation.
Too much voltage.
Cell difference is too much (1V).
Possible faults
Temperature deviation.
Too much cell difference (1V).
Transportation, storage and disposal
Possible solutions
The cutting attachment cannot move
freely. Release the cutting attach-
ment.
Clean the battery connectors with
compressed air or a soft brush.
Speak to your service dealer.
Possible action
Charge the battery.
Use the battery in temperatures between
-10°C (14°F) and 40°C (104°F).
Make sure that the mains voltage aligns with
the voltage stated on the rating plate of the
product.
Remove the battery from the battery charger.
Speak to your servicing dealer.
Possible solution
Use the battery charger in tempera-
tures between 5 °C (41 °F) and 40 °C
(104 °F).
Speak to your servicing dealer.
•
Speak to a person with special training in dangerous
material before you send the product. Obey all
applicable national regulations.
•
Use tape on open contacts when you put the battery
in a package. Put the battery in the package tightly
to prevent movement.
•
Remove the battery for storage or transportation.
15