Troubleshooting schedule
Keypad
Troubleshooting takes place from the keypad.
Keypad
Warning indicator flashing.
No. 3 in figure (5).
The machine does not start
Warning indicator lit.
No. 3 in figure (5).
Battery and battery charger
Troubleshooting the battery and/or the battery charger during charging.
LED display
Red LED blinking
No. 2 in figure (26).
Red LED on
No. 2 in figure (26).
MAINTENANCE
Possible faults
Overload.
Temperature deviation.
The power trigger and the activate
button are pressed at the same time.
Service
Possible faults
The battery is discharged.
Temperature deviation.
Over voltage.
Cell difference too much (1V).
Possible action
The cutting attachment is jamed.
Release the cutting attachment.
Allow the machine to cool down.
Release the power trigger and the
machine is active.
Contact your service agent.
Possible action
Charge the battery.
Use the battery in surroundings
where temperatures are between -
10 °C (14 °F) and 40 °C (104 °F).
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the
battery charger.
Contact your service agent.
English – 19