Test E: Thermal Cut-Out of Electronic Unit
The control module has a built in thermal protection which
NOTICE
stops the compressor operation if the control module
circuit board temperature is higher than 212° F (100° C).
www.norcold.com
Complete the "Diagnostic Pre-Checks."
Remove refrigerator from enclosure,
but keep a power supply (either AC
or DC) connected.
Make sure:
- Upper and lower vents are not
blocked.
- The condenser coil is clean.
- The fan is operating.
- The ambient operating temperature
is lower than 131°F (55° C).
Test the unit.
YES
Does code
5 return?
NO
Replace control module.
Repair complete.
17
SERVICE MANUAL