Test K: Voltage Within Cutout Range but Refrigerator Cuts Out
Complete the "Diagnostic Pre-Checks."
Remove refrigerator from enclosure,
but keep a power supply (either AC
or DC) connected.
Remove refrigerator from enclosure,
but keep a power supply (either AC
or DC) connected.
Make sure:
- Upper and lower vents are not
blocked.
- The refigeratgor is not overloaded
with hot items.
- The ambient operating temperature
is lower than 131°F (55° C).
- If DC power is not connected, a
minimum of 90 VAC is present
Measure input voltage.
- 12 VDC nominal inout voltage is
10.9 - 17.0 VDC.
- 24 VDC nominal input voltage is
23.8 - 31.5 VDC,120 VAC or
240 VAC.
Is
input
voltage within
specification?
Is
unit
overloaded?
Disconnect thermostat wire from
(P)
terminal "P"
on the cooling unit
control module. Test the refrigerator.
Does the
refrigerator still
cut out?
Contact Customer Service.
Series DE/EV0041, Series DE/EV0061, DC0061
NO
Correct input voltage.
YES
YES
Reduce load on unit.
NO
NO
Repair complete.
YES
NOTICE
No.
Description
P
Resistor
24
Removal of resistor will reduce battery
protection (minimum) setting from 10.9
volts to 9.6 volts. This may reduce bat-
tery reserve power and ability to start.
P