PERFORMANCE DATA

Important Notice: Read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
US2000 System
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Influent
Substance
Challenge
Concentration
Standard 42
Chlorine
2.0 mg/L ± 10%
Particulates
at least 10,000
(0.5–<1m) Class I
particles/mL
Standard 53
Minimum 50,000
Cysts
Microsphere/L
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
0.002 mg/L
Lindane
± 10%
Asbestos
Mercury (pH 6.5)
0.006 ± 10%
Mercury (pH 8.5)
0.006 ± 10%
0.009 mg/L
Atrazine
± 10%
Test Conditions
Flow Rate
= 0.6 gpm (2.3 Lpm)
Filter Capacity
= 750 gallons (2839 L)
Inlet Pressure
= 60 psi (4.1 bar)
PH
= 7.5 ±0.5
Lead and Mercury 6.5
= 6.5 ±0.25
Lead and Mercury 8.5
= 8.5 ±0.25
Temperature
= 68°F ±5F° (20°C ±2.5C°)
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating Requirements for US2000 Systems
Pressure
= 30-100 psi (2.1–6.8 bar)
Temperature
= 40-100°F (4.4–37.8°C)
Turbidity
= 5 NTU Max.
The US2000 is Tested and Certified by NSF
International against NSF/ANSI Standard 42 and 53 for
the reduction of substances listed in the table above.
Maximum
Reduction
Permissible
Requirements
Average
Product Water
≥50%
97.5%
≥85%
99.7%
≥99.95%
99.99%
0.010 mg/L
99.2%
0.010 mg/L
99.3%
0.0002 mg/L
98.9%
≥99%
99.0%
0.002 mg/L
96.6%
0.002 mg/L
91.7%
0.003 mg/L
94.5%
Do not use with water that is microbiologically unsafe
WARNING
or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
NOTE: The system must be maintained according to manufacturer's
recommendations, including replacement of filter cartridges. The
contaminants or other substances removed or reduced by this
system are not necessarily in your water.
State of California
Department of Public Health
Water Treatment Device
Certificate Number
11 -
Date Issued: September 9, 2011
Trademark/Model Designation
US2000
Manufacturer: OmniFilter
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Cysts
Organic Contaminants
Atrazine
Lindane
Rated Service Capacity:
750 gallons
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts.
2093
Replacement Elements
1250R
1750R
Inorganic/Radiological Contaminants
Asbestos
Lead
Mercury
Rated Service Flow:
0.6 gpm
• 7 •