4. Remove old sump from sump pit.
NOTICE: Remove all sand, clay, and gravel before installing.
5. Install the 1-1/2 in. PVC rigid pipe on the quick connector.
NOTICE: The quick connector must be tightened.
6. Place Combo pump into sump pit. Make sure vertical float switches can operate freely inside sump pit, once
the Combo pump is firmly seated in the base of the pit, then connect the pump discharge pipe to the sewer pipe
with flexible coupling.
7. Place the battery (sold separately) into the control box. Wiring the leads from controller: Red+ to battery Red+;
Black- to battery Black-. Note: Be sure the battery box ventilation holes are unobstructed. Battery control box
must be set up in a well-ventilated area. Smoking and open flames are prohibited.
NOTICE: If the leads are reversed, the pump will run backward and not pump water.
6
For Professional Technical Support call 1-844-242-2475