4.2 Learning of a transmitter through a transmitter already memorized
Warning: do not use this procedure if you have multiple units in operation, since the store
opening would affect all devices where the channel is stored. In this case, disconnect the
1. Press and release the hidden button of a B.RO transmitter or transmit the item "M" of a CLARUS (*) already
memorized; the control unit emits 3 beeps.
2. Press a key of the transmitter that you want to memorize. The control unit automatically stores all the keys
and it emits a long beep.
3. Release the key of the transmitter, the control unit emits 4 beeps.
If no signal is transmitted in 15 seconds, the control unit automatically exits from the learning mode (4 beeps).
(*) For the menu functions of the CLARUS transmitter, please refer to the instruction of the product.
5
CLIMATIC SENSORS
5.1 Learning of a climatic sensor
1. Press and release the learning button on the control unit; it emits 3 beeps.
2. Press the button on the sensor, the control unit emits a long beep.
3. Release the key of the transmitter, the control unit emits 4 beeps.
If no signal is transmitted in 15 seconds, the control unit automatically exits from the learning mode (4 beeps).
Once the sensor is memorized, you can test the transmission by pressing the key on the sensor.
acoustic signal until the release of the key.
NOTE: the control unit allows to learn one single sensor. The memorization of a second sensor deletes automatically
the first one memorized.
5.2 Checking the motor direction during an alarm
This procedure is necessary to verify the correct wiring of the motor, so that the automation will be closed in case of
alarm.
1. With a transmitter, move the awning / rolling shutter at about halfway and stop it.
2. On the KAIROS sensor, adjust the trimmer to minimum wind (TEST) and rotate the blades of the sensor at a constant
speed for few seconds. On the used AXEM sensor, shake the awning until the intervention of the sensor.
3. The control unit will reclose the awning / rolling shutter during the alarm.
If the awning / rolling shutter moves in opening, remove the power supply from the control unit and swap the motor
cables (black and brown) and make again the test above. If the awning / rolling shutter moves in closing, wait until it is
completely closed; press and release the button on the sensor.
Follow the manuals of the sensors for their setting.
5.3 Deleting of a climatic sensor
1. Press and release the learning button on the control unit; it emits 3 beeps.
2. Press the button on the sensor, the control unit emits two long beeps.
3. Release the key of the transmitter, the control unit emits 4 beeps.
If no signal is transmitted in 15 seconds, the control unit automatically exits from the learning mode (4 beeps).
5.4 Behaviour of the AXEM sensor
The alarms of the AXEM sensor are disabled for all the working time of the control unit and for more 10 seconds. To
delete the waiting time and enable the sensor immidiately, press the learning button on the Axem device.
5.5 LIGHT sensor
The control unit is realized to carry out the opening of the awning / rolling shutter during the transition from Night to
Day, while it realizes the closure of the awning / rolling shutter during the transition from Day to Night.
Moreover, the re–opening for light has been integrated at the end of possible alarms (wind or disconnection).
It is possible to deactivate the light sensor functionality in any moment, and therefore do not make automatically go up
and down the automation depending on the light variation. To deactivate the light sensor proceed as follows:
1. Press and hold a key of a transmitter already memorized (at least 8 seconds). The control unit emits 2 beeps to
6-1622108
rev1
power supply of the control units which shall not be involved.
ITA
ENG
05/03/2020
FRA
ESP
DEU
POR
The control unit emits an
3/4