MAINTENANCE
Important: Use only a good grade hydraulic jack oil. Avoid mixing different types of fluid and NEVER use brake
fluid, turbine oil, transmission fluid, motor oil or glycerin. Improper fluid can cause premature failure of the jack and
the potential for sudden and immediate loss of load. We recommend Mobil DTE 13M.
Adding oil
1. With ram plunger fully lowered and pump piston fully depressed, set jack in its upright, level position. Remove oil
filler plug/screw.
2.
Fill with oil until just below the rim of the oil filler hole. Reinstall the oil filler plug/screw.
Changing oil
For best performance and longest life, replace the complete fluid supply at least once per year.
1. With ram plunger fully lowered and pump piston fully depressed, remove the oil filler plug/screw.
2. Lay the jack on its side and drain the fluid into a suitable container.
Note: Dispose of hydraulic oil in accordance with local regulations.
3.
Fill with oil until just below the rim of oil filler hole. Reinstall the oil filler plug/screw.
Lubrication
A periodic coating of light lubricating oil to pivot points, axles and hinges will help to prevent rust and assure that
pump assemblies move freely.
Cleaning
Periodically check the pump piston and ram plunger for signs of rust or corrosion. Clean as needed and wipe with
an oily cloth.
Note: Never use sandpaper or abrasive material on these surfaces!
Storage
When not in use, store the jack with pump piston and ram plunger fully retracted and air supply disconnected.

TROUBLESHOOTING

Symptom
Jack will not lift load
Jack will lift, but not maintain
pressure
Jack will not lower after
unloading
Poor lift performance
Will not lift to full extension
Possible Causes
• Release valve not tightly closed
• Overload condition
• Release valve not tightly closed
• Hydraulic unit malfunction
• Reservoir overfilled
• Fluid level low
• Air trapped in system
• Fluid level low
5
Corrective Action
• Ensure release valve tightly closed
• Remedy overload condition
• Ensure release valve tightly closed
• Discontinue use, contact your local
Fastenal Representative or visit
www.fastenal.com to locate your
nearest store.
• Ensure load is removed, then drain
fluid to proper level
• Ensure proper fluid level
• With ram fully retracted, remove oil
filler plug/screw to let pressurized
air escape, then reinstall oil filler
plug/screw
• Ensure proper fluid level