05/ 2014
Maximum Frequency
is limited by the maximum output frequency of the frequency
inverter
Setting: 0,00 Hz ... 999,99 Hz
Default: 50,00Hz
Reference Frequency
of the synthetic network
Setting: 0,00...1000,00Hz
Default: 300,00Hz
801 - Setting for voltage reference of the
Reference Voltage
synthetic network
Setting : 0,0V...3000,0V
Default: 200,0V
Acceleration (Clockwise)
Deceleration (Clockwise)
he output frequency is changed after start, stop or brake
t
command or when the reference value is changed.
Setting: 0,00 Hz/s ... 9999,99 Hz/s
Default: 5Hz/s
452 - Multi Function Input 1
Operation Mode
The set point at input MFI1 can be adjusted according to the
connected signal source.
Setting: 1- voltage signal, 0 V ... 10 V
2- current signal, 0 mA ... 20 mA
3- digital input
Default: 1
Operation Mode Digital Output 1
Setting range:
see operation instruction
Default:
run signal
Operation Mode Digital Output 3
Setting range:
see operation instructions
Default:
103 – inverted fault message
Operation Mode Digital Output EM-S1OUTD
Setting range:
see operation instructions
Default:
3 – fault message
44
1)
419
– The speed range of the drive
2)
800
– Setting for frequency reference
1)
420
,
1)
421
- the ramps define how fast
530
532
Quick Start Guide ACU-P