EN
DPS-70 C - DPS-70 CN DIAPHRAGM PUMPS
7.4 INSTALLATION OF DPS MODELS
1
A - STAND TYPE AND CART TYPE
1. Remove the dust proof caps (B,E,F,H,I on page 15)
2. Detach the pump assembly from the support by removing Hex. Bolts (M6).
3. Flip the stand and assemble the pump assy to the right position.
Hex. Bolt (M6)
2
1.
Connect the suction hose to the paint inlet joint (H page 15).
2.
Fix the drain hose to the suction hose with band (3 spots wherever you want).
B
TANK MOUNTING TYPE
1.
Remove the dust proof caps (B,E,F,H,I on page 15)
2.
Assemble the supply lid in its seat, connect the drain hose to the two-way valve for paint recirculation. (as COMMON 1)
3.
Connect the suction hose to the paint inlet joint. (Make sure the seal tape is taped around the suction hose)
Suction hose
12
Stand
Pump
PAINT SUPPLY / SUCTION HOSE
Drain hose
CLOSE UP
Supply Lid
COMMON
1. Connect the drain hose to the
2-way valve for paint recircu-
lation.
Drain hose
Band 3 spots wherever
you want
Suction hose
Fix the drain
hose with the
wing bolt.