Cleaning; Maintenance; Observed Norms - Skymsen ESB-N Manual De Instruccione

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Turn the machine on, hold half of the fruit and press it
down firmly against the crown # 09 or # 10 (Pic-01) and
the juice will run into the cup # 08 (Pic-1) going first
through the sieve # 07 (Pic-01).

5. CLEANING

The equipment shall be totally cleaned and sanitized:
- Before to be used first time
- After every day's operation
-When it has not been used during a long time
- Before to operate it after a long period unused
Some parts of the equipment may be removed for cleaning,
such as:
- Lid
- Juice Chamber
- Crowns
Remove the Lid # 01 (Pic. 01 ), the Large Crown # 09 or the
Small Crown # 10 (Pic. 01) and after the Juice Chamber # 02
(Pic. 01).
Wash all the parts with water and neutral soap.
To assemble follow the inverse path.
Use Your QR Code Reader to access more
information regarding the cares needed
when handling stainless Steel.
6.

MAINTENANCE

Maintenance must be considered a set of procedures
with the purpose to keep the equipment best operating
conditions, therefore increasing the equipment life and
safety.
* Cleaning – check item 5. CLEANING
* Wiring - Check all wires regarding deteriorate conditions as
well as all electric contacts (terminals) regarding tightening
and corrosion .
*Contacts – ON/OFF switches, emergency button, reset
button , electronic circuits etc , check the equipment in order
to assure that all components are correctly working and the
equipment operation is normal .
* Installation – make sure the installation followed item 2
instructions.
1 - Each month check :
- Check the electrical installation
- Measure the voltage at the socket
- Measure the working current and match it with the nominal
current
- Check the tightening of all electric terminals to avoid bad
contacts
- Check electric motor shaft clearance
- Check the wiring for overeating , insulation failures and
mechanical damages .
2 - Each three month checks
- Check electrical components such as ON/OFF switch,
emergency button , reset button, electronic electric circuits,
overeating, insulation failings, or mechanical damages
- Check bearings clearances
- Check retainers, O'rings, V'rings and other sealings.
Use Your QR Code Reader to access
more information regarding safety and
maintenance.
7. APPLICABLE NORMS
Brazilian Norm ABNT NBR NM 60335-1
IEC Norm 60335-2-64
8. ELECTRIC DIAGRAM
ON/OFF