BONAIRE PORTABLE COOLER
Installation
Water Connection / Tank Filling
This unit is compatible with a standard garden hose connection.
Use standard ¾" connection to connect water to the unit.
The overflow is factory fitted. If unit is inside then bleed hose
should be kept inside the tank and regular draining of the tank
will be required. If unit is outside then bleed hose should place
through the overflow fitting SHOULD bleed water during normal
operation at a rate between 6 – 12 Litres per hour (1.5 – 3 gallons
per hour). This is normal and is designed to preserve the quality
of the Cooler and Cooling efficiency of the Unit.
The float valve is factory set and should require no further
adjustment at time of installation.
As an alternative to hose connection, the tank can be manually
filled through the ice door of the front of the unit. The water level
should be set its maximum limit as shown on overflow.
1.Open the Ice door
Note: Water supply line to float valve must be flushed before connecting.
Maximum
Water Level
Indicator
Overflow
2.Slide down the Ice door
Hose Connection
Float
Valve
Page | 8