Remove retainer.
Replace needle with O-ring and spring. Make sure that
the ends of the spring grip (only for the chisel) in the slots
provided.
3.2 w
orking instructions
If the pen stops at a «dead point» and will not start, it can
be set going by gently tapping the stylus.
4. Service / Maintenance
4.1 P
reventive mAintenAnce
Even if the machine still operates perfectly,
the motor should be removed and cleaned
by a specialist after approx. 300 to 400 op-
erating hours.
17