14.5 Connection to the pipe network (see fi gure)
The inlets for connection to the pipe network and to the air vent pipe to the outside can be positioned
both on the right side and on the left side of the control unit.
The intakes for the connection to the
A
suction pipes of the network and to
the pipes exhausting the air outside
can be assembled either on the right
or left side of the unit.
B
Using the sleeve and the metal
clamps delivered with the unit, con-
nect the unit to the air suction pipe.
Using the sleeve and the metal
clamps delivered with the unit, con-
nect the unit to the suction pipe of the
blower motor.
N.B. It is recommended to collocate as close as possible the dust separator to the Industrial Motor
to prevent the pressure drop caused by the pipe network length and by the use of joint elbows
and derivations.
Example of connection to the pipe
network
18
(LINGUA ORIGINALE)
B
A
Industrial Motor suction
Vacuum inlets pipe network
06/06/2016 Rev:2.0.0