Sensor
2.6.2.3. Windows mode procedure
1) Single value teach command sequence:
Buttons are found in menu: "Teach-in SSC1" or "Teach in SSC2" -> "Teach-in Single value
SSC1" or "Teach-in Single value SSC2"
1. Move the target to the position for SP1
A. Press "Teach SP1"
B. Teach-in Result.Teach-in state = e.g. "WAIT FOR COMMAND"
2. Move the target to the position for SP2
A. Press "Teach SP2"
B. Teach-in Result.Teach-in state = e.g. "SUCCESS"
3. QoT is shown in "Quality of Teach" e.g. 255 %
Sensor
2) Dynamic teach command sequence:
Buttons are found in menu: "Teach-in SSC1" or "Teach-in SSC2" -> "Teach in Dynamic SSC1"
or "Teach in Dynamic SSC2"
1. Move the target to the position for SP1
A. Press "Teach SP1 Start"
B. Teach-in Result.Teach-in state = e.g. "WAIT FOR COMMAND"
C. Press "Teach SP1 Stop"
D. Teach-in Result.Teach-in state = e.g. "WAIT FOR COMMAND"
2. Move the target to the position for SP2
A. Press "Teach SP2 Start"
B. Teach-in Result.Teach-in state = e.g. "WAIT FOR COMMAND"
C. Press "Teach SP2 Stop"
D. Teach-in Result.Teach-in state = e.g. "SUCCESS"
3. QoT is shown in "Quality of Teach" e.g. 100 %
SSC
SP2
TP2
ON
Hyst
SSC
SP2
TP1
OFF
ON
window
Sensing distance
SP1
TP1
OFF
Hyst
Sensing distance
SP1
TP1
OFF
Rev.00 - 06 .2021 | MAN PD30CTB IO-Link EN | © 2021 | CARLO GAVAZZI Industri
31