7.2.3. SSC parameters
Parameter Name
Teach-In Select
Teach-In Result
Teach-in State
TP1 (Teach Point 1) of
SP1 (Set point 1)
TP2 (Teach Point 2) of
SP1 (Set point 1)
TP1 (Teach Point 1) of
SP2 (Set point 2)
TP2 (Teach Point 2) of
SP2 (Set point 2)
SSC1 Parameter
(Switching Signal Channel 1)
Set point 1 (SP1)
Set point 2 (SP2)
SSC1 Configuration
(Switching Signal Channel 1)
Switching Logic
Mode
Hysteresis
SSC2 Parameter
(Switching Signal Channel 2)
Set point 1 (SP1)
Set point 2 (SP2)
SSC2 Configuration
(Switching Signal Channel 2)
Switching Logic
Mode
Hysteresis
38
Rev.00 - 06.2021 | MAN PD30CTB IO-Link EN | © 2021 | CARLO GAVAZZI Industr6
Index Dec
Access
(Hex)
58 (0x3A)
RW
59 (0x3B)
-
1 (0x01)
RO
2 (0x02)
RO
3 (0x03)
RO
4 (0x04)
RO
5 (0x05)
RO
60 (0x3C)
-
1 (0x01)
R/W
200 mm for PD30CTBx20...
2 (0x02)
R/W
250 mm for PD30CTBS25...
350 mm for PD30CTBR35...
61 (0x3D)
-
1 (0x01)
R/W
2 (0x02)
R/W
14 mm for PD30CTBx20...
3 (0x03)
R/W
17 mm for PD30CTBS25...
24 mm for PD30CTBR35...
62 (0x3E)
-
1 (0x01)
R/W
200 mm for PD30CTBx20...
2 (0x02)
R/W
250 mm for PD30CTBS25...
350 mm for PD30CTBR35...
63 (0x3F)
-
1 (0x01)
R/W
2 (0x02)
R/W
14 mm for PD30CTBx20...
3 (0x03)
R/W
17 mm for PD30CTBS25...
24 mm for PD30CTBR35...
Default value
0 = No Channel Selected
1 = SSC1
1 = SSC1 (Switching Signal Channel 1)
2 = SSC2 (Switching Signal Channel 2)
-
0 = Idle
4 = Wait for command
0 = Not OK
0 = Not OK
0 = Not OK
0 = Not OK
-
20 ... 225 mm for PD30CTBx20...
20 mm
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
-
0 = High active
1 = Single Point
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
-
20 ... 225 mm for PD30CTBx20...
20 mm
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
-
0 = High active
1 = Single Point
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
Data range
Data Type
UIntegerT
-
-
0 = Idle
1 =Success
RecordT
5 = Busy
7 = Error
0 = Not OK
RecordT
1 = OK
0 = Not OK
RecordT
1 = OK
0 = Not OK
RecordT
1 = OK
0 = Not OK
RecordT
1 = OK
-
-
IntegerT
IntegerT
-
-
0 = High active
UIntegerT
1 = Low active
0 = Deactivated
1 = Single Point
2 = Window
UIntegerT
3 = Two Point
4 = FGS
UIntegerT
-
-
IntegerT
IntegerT
-
-
0 = High active
UIntegerT
1 = Low active
0 = Deactivated
1 = Single Point
2 = Window
UIntegerT
3 = Two Point
4 = FGS
UIntegerT
Length
8 bit
-
8 bit
8 bit
8 bit
8 bit
8 bit
-
16 bit
16 bit
-
8 bit
8 bit
16 bit
-
16 bit
16 bit
-
8 bit
8 bit