NOTE: The following procedure applies to both
framed or frameless cabinet installations.
1. Run house power cable between service panel and
hood location.
2. There are 2 pairs of recessed holes on each side
of the top of the hood (on rear: A and B, on front
C and D on illustration beside); these holes allow
the range hood to hang on the brackets (previously
installed).
HORIZONTAL EXHAUST INSTALLATION ONLY
3. Temporarily hang the hood on the brackets using its
2 recessed REAR HOLES (A and B). While holding
the hood, run the house power cable into the hood
through the strain relief previously installed
5 on page 9.
4. Unhook the rear holes from the brackets and hang
the hood using its 2 recessed FRONT HOLES (C and
D). While holding the hood, go to step
VERTICAL EXHAUST INSTALLATION ONLY
5. Hang the hood on the brackets using the 2 recessed
FRONT HOLES (C and D). While holding the hood,
tighten an appropriate strain relief, 1/2" diameter
(not included) to the power cable, then insert the
strain relief in the knockout hole.
6. Connect the ductwork to the hood and use metal foil duct tape to make joints secure and air-tight. Make sure
the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.
7. For framed cabinet, secure the hood to the EZ1
brackets using 4 no. 8-18 x 1/2" metal screws with
washers (screws and washers included in parts
bag). Insert 2 screws and washers per side, in the
slots (as shown in inset on illustration beside).
8. For frameless cabinet, secure the hood to the
cabinet using 4 no. 8 x 5/8" round head wood
screws (screws and washers included in parts bag).
Insert 2 screws and washers per side, in the slots (as
shown in inset on illustration beside).
9. Attach power cable to the hood using the strain
relief.
Install the hood (EZ1 brackets)
in step
6.
DUCTED INSTALLATIONS ONLY
A
C
A
FRAMED CABINET
M
ETAL
S
CREWS
13
D
B
B
FRAMELESS CABINET
W
OOD
S
CREWS