INSTALL DUCTWORK (DUCTED INSTALLATION ONLY)
1. Determine whether hood will discharge vertically
(3¼" x 10" or 7" Round) or horizontally (3¼" x 10"
only).
2. Run ductwork between the hood location and a roof
cap or wall cap.
3. Choose a straight, short duct run to allow the hood to
perform most effi ciently. Long duct runs, elbows and
transitions will reduce the performance of the hood.
Use as few of them as possible. When possible, use
at least 2 foot straight runs before any turns. Larger
ductwork may be required for best performance with
longer duct runs.
4. Install wall cap or roof cap (sold separately). Connect
metal ductwork to cap and work back towards the
hood location. Use 2" metal foil duct tape to seal the
joints between ductwork sections.
1. If present, remove all protective polyfi lm from the
hood and/or parts. Remove 7" Round Duct Plate
from top/back of hood (see illustration at right).
Keep the screws for further use.
2. Using the fi nger cup, remove the Hybrid Filters from
the hood by pushing down and tilting fi lters out.
S
OFFIT
C
ABINET
18"
MIN
ABOVE COOKING SURFACE
NOTE: Distances over 30" are at the installer and user

PREPARE THE HOOD

SCREWS
8
R
OOF CAP
3¼"
7"
ROUND DUCT
(F
OR VERTICAL
DISCHARGE
H
OOD
- 30"
MAX
discretion.
B
C
10"
X
OR
)
H
OUSE WIRING
(T
)
OP OR BACK OF HOOD
W
ALL CAP
3¼"
10"
X
DUCT
(F
)
OR HORIZONTAL DISCHARGE
7" ROUND
DUCT PLATE

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Elite 51413 serie

Tabla de contenido