Technical Specifications - baltur BTL 0 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL SPECIFICATIONS

MODEL
Burner output
Thermic capacity
Fuel max. viscosity
E
Electrical feeding
N
Motor
G
Pre-heater
L
I
Tranformer
S
Absobed electrical power *)
H
Weight
Operation
MODEL
Burner output
Thermic capacity
Fuel max. viscosity
Electrical feeding
Motor
Pre-heater
Tranformer
Absobed electrical power *)
Weight
Operation
*) Total absorption at start with ignition transformer on.
BTL 0
min kg/h
1,80
max kg/h
3,6
min kW
21,3
max kW
42,7
(light-oil)
kW
W
- -
kW
0,150
kg
BTL 6
min kg/h
2,70
max kg/h
6,3
min kW
31,9
max kW
74,3
(gasolio)
kW
W
- -
kW
0,150
kg
20 / 64
0006080748_20072
N° 0002270660
REV.: 25/09/00
BTL 0H
BTL 4
1,57
2,20
3,6
4,7
18,6
26,0
42,7
56,1
5,5 cst / 20° C
1,5° E / 20° C
1 ~ 230V ±10% - 50Hz
0,10
30-110
- -
40 mA - 15 kV
0,270
0,150
12
ON / OFF
BTL 6H
BTL 10
2,70
5,10
6,3
10,0
31,9
60,2
74,3
118,0
5,5 cst / 20° C
1,5° E / 20° C
1 ~ 230V ±10% - 50Hz
0,10
240
- -
40 mA - 15 kV
0,390
0,150
12
ON / OFF
BTL 4H
2,20
4,7
26,0
56,1
30-110
0,270
BTL 10H
5,10
10,0
60,2
118,0
240
0,390