The Electrobrush switches itself off
but the indicator lamp remains green
The overheating protection mechanism
has been activated by the appliance
overheating or because of a blockage.
^ Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
The Electrobrush has to cool down. To
speed this up:
^ Reconnect the vacuum cleaner to the
Electrobrush and switch the vacuum
cleaner on.
^ Raise the suction tube and
connection socket to the vertical
position.
The Electrobrush will be ready for use
again after about ten minutes.
The light tube needs changing
See illustrations i and j
Light tube specification:
– Fitting: G5
– Size: 16 x 212
– Wattage: 6 watts
– Shade: cool white
^ Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
^ Release the Electrobrush connection
socket.
^ Loosen the four fixing screws
underneath the Electrobrush a.
^ Take off cover b and roller connector
c.
^ Unscrew the four fixing screws d
which are now visible and separate
the base section e from the top
section f.
^ Replace the light tube.
^ Reassemble the Electrobrush by
reversing the procedure.

Maintenance and care

Removing threads and hairs
See illustration k
^ Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
^ Cut any threads or hairs that have
become entangled in the roller with a
pair of scissors.
There is a groove along the roller to
help you. Then run the vacuum cleaner
to vacuum up the bits.