RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/attachment
combination is a responsibility of the original truck
manufacturer and may be less than that shown on the
attachment nameplate. Consult the truck nameplate.
Truck Relief Setting
Low Pressure
155 bar
189 bar
NOTE: The attachment valve has separate pressure
relief control, see Installation Step 9 for adjustment.
Truck Flow Volume
20G, 28G, 36G,
44G, 52G, 64G
70G, 77G
Cascade 20G–77G Non-Revolving Clamps are compatible with
SAE 10W petroleum base hydraulic fluid meeting Mil. Spec.
MIL-0-5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact
Cascade.
Flow less than recommended will result in reduced system
performance.
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A) ISO (ITA)
A
Class II
Class III
Class IV
GA0028.eps
Auxiliary Valve Functions
Check for compliance with ISO standards.
6033701-R6 EN
(see attachment nameplate)
High Pressure
190 bar - Recommended
250 bar - Maximum
Recommended
Min.
19 L/min.
28 L/min.
26 L/min.
45 L/min.
Minimum
Maximum
380.0 mm
381.0 mm
474.5 mm
476.0 mm
595.5 mm
597.0 mm
GA0082.eps
Max.
56 L/min.
75 L/min.
Tilt
Forward
Hoist Down
Hoist Up
Tilt Back
GA0380.eps
Carriage – Clean carriage bars and
inspect carriage bars. Make sure the
bars are parallel and that ends are
flush. Repair any damaged notches.
Sideshift
Left
Release
Clamp
Sideshift Right
1