WARNING
RISK OF SERIOUS INJURY:
POTENTIAL FOR INJURY: The use of worksurfaces that do not comply with the Steelcase defined criteria and limitations could cause personal injury or property damage due to pinch
points, instability, or other problems.
POTENTIAL FOR NON-COMPLIANCE: The use of worksurfaces that do not comply with Steelcase criteria VOIDS any Steelcase claims of compliance with ANSI/BIFMA, UL, LEED,
or other applicable requirements. The use of non-Steelcase worksurfaces on Steelcase adjustable-height bases may NOT be accepted as compliant to municipal electrical codes or
OSHA federal workplace standards, because this use may not create an NRTL (UL, ETL, etc.) listed product. Steelcase is not responsible for the ultimate determinations of compliance
for height-adjustable bases with non-Steelcase worksurfaces. Steelcase assumes NO liability for lack of standards compliance in these instances.
WARRANTY RESTRICTIONS: The use of non-Steelcase supplied worksurfaces VOIDS all Steelcase warranties, expressed or implied.
DISCLAIMER: The use of non-Steelcase worksurfaces is NOT recommended. Any use of a non-Steelcase worksurface requires additional investigation by the customer regarding the
appropriateness for use. It is the sole responsibility of the customer to determine the suitability and safety of the selected worksurface construction and attachment means. The following
information is provided as a guideline, but does not address all potential issues. Customers should seek professional guidance as to the appropriateness of their chosen worksurface.
MANDATORY REQUIREMENTS REGARDLESS OF WORKSURFACE MATERIAL OR CONSTRUCTION:
FASTENERS: Adjustable-height bases include fasteners intended for use with Steelcase worksurfaces.
These fasteners may potentially also be suitable for worksurfaces meeting the following criteria:
Medium-density or higher particleboard or fiberboard cores with High-pressure laminate (HPL),
Low-pressure laminate (LPL) or veneer & backers
Thickness of .984" (25.0 mm) or greater
Fasteners located a minimum distance of .984" (25.0 mm) from any edge
Any other worksurface construction will require different and/or additional fastening means and these means
must be determined by the project's designer, architect, or engineer. For example, solid-surface materials
should use appropriate threaded inserts and corresponding fasteners or similar attachment means.
In all cases, all fastener locations provided in the base attachment features MUST be used (e.g. if attachment
plate has 6 screw holes, all 6 holes must be used for attachment).
FLAMMABILITY: Any worksurface or similar large part > 10ft ^ 2 must have a flame spread < 200 and
a smoke developed index < 450 when tested per UL 723.
SHARP EDGES: All accessible edges of the worksurface must meet 1439 test for sharp edges.
DIMENSIONAL LIMITATIONS:
Worksurface depth not to exceed 28.0" (711.2 mm)
Worksurface width not to exceed 70.0" (1778 mm)
FOLLOW ALL WARNINGS PROVIDED FOR BASE + WORKSURFACE.
WORKSURFACE
WIDTH
2.7"
68.58 MM
BASE-ONLY
WORKSURFACE
DEPTH
Page 5 of 43
146381 Rev B