EN
DESCRIPTION
Compressed air operated piston-type reciprocating pump. This ultra high pressure pump is compatible with mineral and synthetic grease and
suitable for applications where extreme grease pressure is needed.
!
WARNING! THIS EQUIPMENT IS DESIGNED FOR PUMPING GREASE. DO NOT PUMP ANY OTHER FLUID.
WARNINGS - ULTRA HIGH PRESSURE EQUIPMENT!
WARNING! Carefully read all instruction manuals, tags, and
!
labels before operating the equipment. This equipment is for
professional use only.
• The use of non compatible fluids may cause damage in the pump and
serious personal injury. This equipment is not intended for use with
fluids that fall within the Group 1 fluid as defined that are explosive,
extremely flammable, highly flammable, flammable, very toxic, toxic,
oxidizing or where the vapor pressure if greater than 0,5 bar (7 psi)
above the pressure atmospheric at the maximum allowable
temperature.
• The pump generates ULTRA HIGH PRESSURE. WARNING! Do not exceed
the maximum air inlet pressure of 7 bar (100 psi). It is STRONGLY
RECOMMENDED to use a pressure relief valve in the air input of the
pump, set to 7 bar (100 psi) max, to avoid overpressure in the pump.
INSTALLATION
The pump can be mounted directly on 50 kg (120 lb) and 185 kg (400 lb) drums. However, it is strongly recommended the use of a lifter/RAM and
a coupled plate.
WARNING! ATEX installation: be sure to connect the grounding
!
cable correctly (fig 1 and 2).
When mounted directly on a drum, It is recommended to use a sturdy
cover due to weight considerations.
Example: mounting with cover (418026/418018) for 185/50 kg
(400/120 lb) drum. Insert the pump through the cover and fasten it with
the enclosed screws. Insert the pump into the drum and fasten the cover
onto the drum firmly (see figure 1). For heavy greases, the use of a
follower plate is recommended (417015/417016).
It is also possible to install the pump in tanks/containers equipped with
a 3" female camlock connection, using our 3" camlock adapter kit
(534900), usually in horizontal/inclined position.
Pump can be placed on a flat surface with the available stand 534906.
ATEX: securely fasten the supplied grounding cable to
the body of the pump, and firmly attach the clamp to
a grounded element of the installation
534900
4
853 831 R. 02/20
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• A direct hit against the human body may result in an injury.
• The use of some kind of lifter is strongly recommended for manipulating
or servicing tasks, since the pump weighs aprox. 59 kg (130 lb).
• This unit may have STORED PRESSURE, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of this
unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only Samoa Industrial, S.A.
genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identification labels may invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should
be suitable for the maximum possible pressure generated by the
pump/air motor. If the systems cannot be designed to take the
maximum pressure produced by the pump, safety valves or diverter
valves should be fitted.
Securely attach the clamp of
supplied cable to a ground
element of the installation
Ensure the grounding
cable is securely fastened
to the pump body
Fig. 1
Fig. 2
534907
534900
female camlock
from bulk tank
418026/418018