Descargar Imprimir esta página

Safety Requirements - PolyVision a3 CeramicSteel Serif Guia De Instalacion

Publicidad

Idiomas disponibles

Idiomas disponibles

SAFETY REQUIREMENTS

a
CeramicSteel Serif - Wall Mounted Frameless Dry
3
Erase Board, Non-Seismic Applications.
The building's Engineer of Record must be consulted
to determine if there are any seismic requirements.
CAUTION
CRUSH HAZARD.
board could result in personal injury.
ATTENTION
RISQUE D'ÉCRASEMENT. Ne pas attacher
la planche de manière sûre pourrait entrainer
des blessures personnelles.
SAFETY INSTRUCTIONS
Read all assembly directions before beginning installation.
Building construction varies greatly. The Building's Engineer of Record is
responsible for the design of building walls which the boards are attached
to and must verify the adequacy of the mounting hardware, even if
provided by Polyvision.
The building owner or designated agent is responsible for verifying that
the installation is in compliance with all local codes and regulations.
INSTRUCTIONS DE SÉCURITÉ
Lisez l'ensemble des instructions d'assemblage avant de démarrer
l'installation.
La construction des bâtiments varie grandement. L'ingénieur
d'enregistrement du bâtiment est responsable de la conception des murs
sur lesquels sont attachées les planches et doit vérifier que le matériel
de montage est adéquat, même si ce dernier est fourni par PolyVision.
Le propriétaire du bâtiment ou l'agent désigné a la responsabilité de
vérifier que l'installation est conforme à l'ensemble des codes et
réglementations locaux.
Visit our website for a comprehensive Installation Guide:
polyvision.com/resources/installation
Or scan follow QR code:
Verify Wall Construction
C AUTION: Adequate wall construction is required
to support the weight of the board. Minimum wall
construction must be capable of supporting weight
amounts listed in Table-1 on page 3.
Failure to properly secure
Minimum Required Wall Construction
Drywall with metal studs:
Must be at least 25 ga. (0.018" or .5 mm thick)
33 ksi steel studs 38 mm x 89 mm (1.5" x 3.5")
Studs on maximum 610 mm (24") centers
Must be at least 16 mm (5/8") thick Type X
gypsum drywall for the US or 12 mm (1/2")
thick for EU
32 mm (#6 x 1-1/4") drywall screws on
305 mm (12") centers
Drywall with wood studs:
Stud grade SPF, DF-L, or Hem-Fir
38 mm x 89 mm (1.5" x 3.5")
Studs on 610 mm (24") centers
Must be at least 16 mm (5/8") thick
Type X gypsum drywall for the US
32 mm (#6 x 1-1/4") drywall screws
on 305 mm (12") centers
or 12 mm (1/2") for EU
Page 2 of 7
Doc # 146743 Rev A