Error
displayed
B
GB
Parasite flame/flame detection
F
circuit anomaly on the single
Main valve control circuit
Flt00
Anomaly circuit voltage of
Flt01
Flt02
Watchdog circuit anomaly
Flt03
Microcontroller door anomaly
Flt04
Flt05
Pilot valve circuit anomaly
Limit of 5 unlocks in 15
Flt06
Flt08
Power supply circuit anomaly
Flt09
Flt0A
Communication errors in the
Flt0[
Error in the control of the
Flt0E
Ft1E
Control panel hardware error
Ft2E
Control panel hardware error
Problem type
Single burner locked
Ionization electrode dirty or not hit by the flame
burner
anomaly
reference
Eeprom anomaly
The burners have been unlocked 5 times in 15
minutes exceeded
Power was cut to the device when another type
Generic anomaly
Resonator anomaly
Ionization electrodes dirty or not hit by the flame
All burners locked
Gas is leaking from one valve that caused the
unwanted lighting of a second burner while the
This problem is caused by flame in the second
control logic
compromised the support of the keypad by the
keypad
Possible cause
No gas
The cook top is not grounded
Ionization electrode wired incorrectly
Failure at the circuit
Failure at the circuit
Failure at the circuit
Failure at the circuit
Failure at the circuit
Failure at the circuit
Failure at the circuit
minutes
Failure at the circuit
of failure had occurred previously
Failure at the circuit
No gas
The cook top is not grounded
first was being lit.
burner for more than 10 seconds.
Failure at the circuit
A mechanical deformation could have
glass
Circuit failure
Circuit failure
24
Possible solution
Restore the gas and unlock the
burners
Clean or reposition the
electrode and unlock the
burners
Check the cables and unlock
the burners
Check the wiring
Replace the device
Replace the device
Replace the device
Replace the device
Replace the device
Replace the device
Replace the device
Wait 15 minutes before
unlocking the burners
Replace the device
Unlock the burners
Replace the device
Restore the gas and unlock the
burners
Clean or reposition the
electrodes and unlock the
burners
Check the cables and unlock
the burners
Replace the defective valve
Replace the device
Wait several seconds for the
keypad to recalibrate. If the
error persists, turn the power
off and on. If the error still
persists, replace the device.
Check that the control panel
board is correctly inserted into the
connector. Replace the device
Check that the control panel
board is correctly inserted into the
connector. Replace the device