EN
Cancelling the pressing
procedure
▶
Press and hold stop button.
Rectifying malfunctions
Fault
Unable to activate the
pressing tool out of idle
state, no LEDs are lit.
Green LED flashes.
Green LED lights up and
red LED flashes.
Green LED flashes and
roller drive moves back to
its starting position.
Red LED flashes.
30
Result
✓ The roller drive in the pressing tool
Cause
Mains cable is not
connected.
Mains cable or mains
plug is defective.
Retaining pin has
been inserted incor-
rectly or has not been
pushed in until the
stop position is
reached.
Contacts for pressing
jaw detection on the
pressing cylinder are
dirty.
Without the press-
fitting, the pressing
jaw is closed.
Closing sensor on
pressing jaw is
defective.
Adapter jaw is not
correctly hooked into
the pressing collar.
Pressing attachment
is not compatible with
the pressing tool.
Retaining pin has
come loose.
Start button was
released too soon.
returns to its starting position. The
pressing procedure must be repeated for
a complete press connection. The
pressing attachment must not be
removed or rotated at this time.
Action
▶ Connect the mains plug to the power
supply system.
▶ Have the mains cable and mains plug
examined at an authorised repair
shop and replaced if necessary.
▶ Push the retaining pin in until the stop
position is reached.
▶ Clean the contacts on the pressing
cylinder and on the pressing jaw or
adapter jaw.
▶ Place the pressing jaw on the
pressfitting.
▶ Replace the pressing jaw.
▶ Hook the adapter jaw in again.
▶ Only pressing attachments with the
compatibility mark
be used.
▶ Push the retaining pin in until the stop
position is reached. Red LED flashes
and signal tone sounds.
▶ Repeat the pressing operation.
▶ Press start button again. Roller drive
moves to its starting position.
▶ Repeat the pressing operation: press
the start button for at least 2 seconds.
18014400405789195-1 © 02-2018
are allowed to
968.400.00.0 (00)