Broan Best WC26E Manual Del Usario página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL THE HOOD, cont'd
7. Carefully place the decorative flue on the
hood. Fig. 14.
ROOMS WITH 10-FOOT CEILINGS
Rooms with 10-foot ceilings require flue ex-
tension model AEWC26xB, available from
your local dealer.
8. Discard the upper flue supplied with the
product.
Replace it with the flue
extension.
9. Raise the upper flue until its holes align
with holes in the flue mounting bracket
(located on ceiling). Fig. 15.
10. Secure the flue with (2) 3.9x9.5mm
mounting screws. Fig. 15.
11. Secure the lower flue to the upper flue
with (1) 2.9x9.5mm mounting screw. Drill
the hole (1/16" Diameter) in the upper
flue. Fig. 16.
UPPER
FLUE
LOWER
FLUE
MOUNTING SCREWS
- 13 -
FIG.14
3.9x9.5mm
FIG.15
2.9x9.5mm
MOUNTING SCREW
FIG.16

Publicidad

Tabla de contenido
loading

Tabla de contenido