Cut the seal 1/4" (6 mm) longer than the bridge
11
member. Cut the final 1-1/4" (32 mm) of the seal
off each end of the flange.
Bridge Member
Flange
1-1/4"
(32 mm)
Seal
1-1/4"
Seal
(32 mm)
1/4" (6 mm) Longer
Insert two plugs on the magnet side and two
16
bushings on the pivot side.
Bushing
Plug
Plug
Bushing
Plug
To adjust, remove the screws and turn the
21
adjustment block screws until aligned. Reinstall
the screws.
Troubleshooting
Installation
Recommended Action
1. The door does not fit.
A. Confirm the correct receptor is installed.
2. The frame and/or door are not aligned and
A. Perform the adjustment procedure in Steps 20 and 21.
plumb.
3. The seal is deformed.
A. Soak the seal in hot water. The seal will regain its shape.
Operation
Recommended Action
1. There is leaking at the bottom of the door
A. Tighten the crossmembers and reseal.
frame.
2. There is leaking from the door area.
A. Confirm the correct areas are sealed per Steps 18, 22, and 23. Reverse the pivot side of the door.
3. The door contacts the base when opened or
A. Remove the door and insert a second nylon washer on the bottom pivot pin. See Step 17.
closed.
1187937-2-C
On a work surface assemble the flange and strike
12
post to the bridge members with eight screws.
The flange should be on the pivot side of the
frame.
Flange
Strike Post
Magnet
Seal
Bridge Member
Front
#8 x 1"
Install the pivot pin and nylon washer.
17
Nylon
Washer
Bottom
Pivot Pin
Bushing
Install a cushion into the two flange slots and
22
snap into place.
Confirm that the bridge members are flush with
13
the flange and the strike post. To adjust loosen
the screws and move the bridge member up or
down.
Front View
Flush Alignment
Bridge Member
Flange
Strike Post
Bridge Member
Seal the bottom of the door panel frame with
18
silicone sealant.
Pivot Side
Strike Side
Seal here.
Seal here.
Outside the shower, apply 100% silicone sealant
23
to the entire shower door length along the
bottom.
100% Silicone Sealant
Seal here, outside only.
2
Determine right or left pivot side. Confirm there
14
are no obstructions in the door path. Illustrations
show right pivot throughout. Reverse for left side
pivot installations.
Left Pivot
Right Pivot
Pivot
Pivot
Side
Side
100˚
100˚
18-7/8"
(479 mm)
Lift the door panel, align the bottom pivot hole
19
and pin, and lower into place. Align the top pivot
hole and top bushing. Insert the long end of the
pivot pin from above.
Top Pivot Pin
Bushing
Pivot Hole
Slide the seal back and apply a bead of silicone
24
sealant at each side of the door opening. Allow
the silicone sealant to cure 24 hours before using.
Seal here.
Seal
STERLING® Warranty – Bath and Shower Doors
5-Years Limited
SP2375 5100 Series 5300 Series 5400 Series 6300 Series 6500 Series
3-Years Limited
1500 Series 1900 Series 2200 Series 4600 Series 4700 Series 4800 Series 4900 Series 5900 Series
1-Year Limited
500 Series 600 Series 660 Series 670 Series 690 Series 950 Series 2300 Series 3100 Series
Based on the classification specified above, STERLING bath and shower doors are warranted to be free of
manufacturing defects within the time of the specified model's limited warranty from date of sale.
Kohler Co. will, at its election, repair, rectify or replace a fixture when inspection by Kohler Co. discloses any such
defects occurring in normal usage within the time period of coverage stated above. Kohler Co. is not responsible
for removal or installation costs where replacement is indicated. Damages due to improper handling, installation or
maintenance are not considered manufacturing defects and are not covered by this warranty. This warranty is valid
for the original, consumer purchaser only.
To obtain warranty service, contact Sterling, either through your plumbing contractor, home center, wholesaler or
dealer, or by calling or writing Sterling, Consumer Services, 444 Highland Drive, Kohler, Wisconsin 53044, 1-800-
783-7546.
TO THE EXTENT PERMITTED BY LAW, ALL IMPLIED WARRANTIES INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
KOHLER CO. AND SELLER HEREBY DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty
lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and
exclusions may not apply to you. This warranty gives you specific legal rights. You may have other rights which
vary from state/province to state/province.
This is the exclusive written warranty for Kohler Co.
Make sure the grooves and flanges are engaged.
15
Secure with four screws on each side.
Groove
Groove
and
and
Flange
Flange
#8 x 5/8"
Confirm the door is square to the framework.
20
Check for smooth operation. Adjust as needed.
©2014 Kohler Co.