5566-CARRIER NON-RECHARGEABLE BATTERY CARRIER
WARNING: The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is a
proprietary shape and design and will only fit in the XPP-5562, XPR-5564, XPP-
5566, and XPR-5568 Angle Lights. Do not attempt to use this battery pack in any
other light. Do not attempt to use any other battery pack in this light.
The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is designed to
fit 3 AA batteries. In order to maintain the XPR-5564's Intrinsically Safe rating, the only
AA batteries certified for use with this light are the Energizer EN91 or Energizer E91.
Do not attempt to use any other brand or model of AA batteries with this light.
Do not attempt to use any type of rechargeable AA batteries with this light.
Installing or replacing the batteries
y Begin by positioning the 5566-CARRIER Non-Rechargeable Battery Carrier with the
arrow pointing to the left.
y Using 3 – AA Energizer EN91 or Energizer E91 (make sure that all 3 batteries are
of one or the other model...do not use a combination of the two), install the batteries
per the diagram located on the base of the battery carrier.
y Take care not to bend any of the battery contact springs, and to make sure that all 3
batteries are properly seated before installing into the angle light.
NOTE: The battery carrier cover will only fit one way. It is not possible to install it
in a reversed position.
The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is ready to
install into the Angle Light. Installation of the 5566-CARRIER Non-Rechargeable
Battery Carrier into the Angle Light is the same as installing the 5568-BATT Lithium-ion
Battery Pack. Please see the instructions listed above in the 5568-BATT LITHIUM-ION
RECHARGEABLE BATTERY PACK section.
PLACING THE ANGLE LIGHT INTO THE CHARGER
The Nightstick 5568-CHGR1 charger is designed to securely hold a properly installed
XPR-5564 Angle Light in place under conditions up to and including 9g of lateral force
meeting the requirements of NFPA 1901 (2009).
WARNING: Installing the Angle Light into the charger MUST be done using the
following steps. Failure to do so could damage the charger or its ability to hold
the Angle Light securely in place.
The spring-loaded tab located on the bottom of the charger, is designed to hold the
bottom base of the Angle Light securely in place.
y Firmly grip the Angle Light in one hand and press the bottom of the Angle Lights base
downward onto the black spring-loaded tab and then push the base of the Angle Light
forward into the charger until it slips past the spring-loaded tab and snaps into the charger.
Confirmation of proper installation can be seen in the LED Charge Indicator Light.
When the Angle Light is properly installed in the charger, and power is being supplied by
the Nightstick AC or DC Power Supply, the LED Charge Indicator Light on the charger
will light up constant RED indicating that the unit is being charged.
REMOVING THE ANGLE LIGHT FROM THE CHARGER
y Firmly grip the Angle Light in one hand and press down the black spring-loaded tab
with your thumb using your opposite hand and pull the Angle Light out of the charger.
y The light has now been safely removed from the charger and is ready to use.
CHARGING THE ANGLE LIGHT
WARNING: Use only the supplied Charger, Lithium-ion Rechargeable Battery Pack
and AC or DC Power Supply for charging. Do not attempt to charge this light with
non-rechargeable or rechargeable AA batteries installed.
y The time required to charge the Angle Light is conditional on the remaining charge left
in the Lithium-ion Rechargeable Battery Pack at the time of charging. The maximum
charge time required is approximately 6 hours.
y Fully charge the Lithium-ion Rechargeable Battery Pack before the first use, or if the
Lithium-ion Rechargeable Battery Pack has been unused for several months.
y Install the Angle Light into the charger using the exact method described in this
Instruction Manual above ("PLACING THE ANGLE LIGHT INTO THE CHARGER").
WARNING: Failure to do so could damage the charger and/or the light.
y When the Angle Light is properly seated in the charger, the LED Charge Indicator
light will turn solid RED indicating that the Lithium-ion Rechargeable Battery Pack is
charging. The Lithium-ion Rechargeable Battery Pack is fully charged when the LED
Charge Indicator light turns GREEN.
y The Lithium-ion Rechargeable Battery Pack does not have any Recharge Memory
Effect, therefore placing the Angle Light in the charger prior to full depletion of the
battery does not adversely affect the battery life. The Angle Light can be kept in the
charger indefinitely without any negative impact on the battery or the battery life.
OPERATION
THE XPR-5564 HAS 3 SEPARATE LIGHTING MODES:
Flashlight Modes
To activate the Flashlight, press and release the Flashlight Switch. To turn the
Flashlight off, press and release the Flashlight Switch one more time.
Floodlight Modes
To activate the Floodlight, press and release the Floodlight Switch. The default
mode will be High-brightness. To turn the Floodlight off, press and release the Floodlight
Switch one more time.
Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com
Dual-Light Mode
Dual-Light mode allows the user to turn on both the Flashlight and the Floodlight
at the same time. Dual-Light mode can be activated by simply pressing the Flashlight
Switch and then the Floodlight Switch at the same time. The user can leave Dual-Light
mode and go back to either Flashlight or Floodlight mode simply by pressing the switch
for the mode that they wish to turn off. To turn both lights off, simply press each of the
switches independently.
WARRANTY
LIMITED LIFETIME WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in workmanship
and materials for the original purchaser's lifetime. The Limited Lifetime Warranty
includes the LEDs, housing and lenses. Rechargeable batteries, chargers, switches,
electronics and included accessories are warranted for a period of two years with proof
of purchase. Normal wear and failures which are caused by accidents, misuse, abuse,
faulty installation and lightning damage are excluded.
We will repair or replace this product should we determine it to be defective. This
is the only warranty, expressed or implied, including any warranty of merchantability or
fitness for a particular purpose.
For a complete copy of the warranty, go to www.nightstick.com/nightstick-product-
support/warranties. Retain your receipt for proof of purchase.
Mode D'emploi
Intrant™
Veuillez lire ces directives avant d'utiliser votre lampe à angle admissible
rechargeable Nightstick XPR-5564 à sécurité intrinsèque. Elles contiennent des
renseignements importants et des consignes d'utilisation.
LA LAMPE XPR-5564 EST APPROUVÉE POUR UTILISATION
Bayco Products, Inc.
640 S. Sanden Blvd., Wylie, TX 75098
Ex ia FLASHLIGHT FOR USE IN HAZARDOUS LOCATIONS
For use with Bayco Li-ion Battery Pack 5568-BATT or
5566-CARRIER with 3 AA Energizer Type EN91 or E91
E 114304
ID 4003544
ELECTRICAL SAFETY
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
0359
Control Drawing: 5568-CERT-DWG1-03
AVERTISSEMENTS – SÉCURITÉ INTRINSÈQUE
y AVERTISSEMENT: Utiliser uniquement le bloc-piles approuvé Nightstick 5568-BATT
au lithium-ion rechargeable ou les piles non rechargeables approuvées et énumérées
dans le point 4 des conditions particulières d'utilisation.
y AVERTISSEMENT: Pour éviter l'inflammation d'atmosphère dangereuse, ne pas
ouvrir une pièce dans un endroit dangereux. Cette tâche doit UNIQUEMENT être
effectuée dans une zone non dangereuse. AVERTISSEMENT: Pour éviter l'inflammation
d'atmosphère dangereuse, le bloc-piles approuvé et rechargeable au lithium-ion
Nightstick 5568-BATT doit être uniquement chargé dans une zone non dangereuse.
y AVERTISSEMENT: Lorsque vous utilisez les piles non rechargeables dans le
PORTE-BATTERIE Nightstick 5566, utiliser uniquement les piles Energizer EN91 ou
Energizer E91.
y AVERTISSEMENT: Pour éviter l'inflammation d'atmosphère dangereuse, les piles
non rechargeables AA doivent être changées dans une zone non dangereuse.
y AVERTISSEMENT: Pour réduire le risque d'explosion, ne pas mélanger des
nouvelles piles non rechargeables avec des vieilles piles non rechargeables, ou
mélanger des piles non rechargeables de différents manufacturiers.
y AVERTISSEMENT: La substitution de composants peut compromettre la sécurité
intrinsèque.
y AVERTISSEMENT: Cet équipement peut générer des décharges électrostatiques
car la capacitance mesurée est de 4 pF des parties métalliques par rapport à la terre.
DIRECTIVES SPÉCIALES POUR LA SÉCURITÉ INTRINSÈQUE
y Pour votre propre sécurité, toujours confirmer la charge d'une zone dangereuse ou
potentiellement dangereuse à l'endroit où la lampe à angle doit être utilisée.
y Seuls les dispositifs directement raccordés aux appareils conformes avec les séries
IEC 60950 sont acceptées.
INS-XPR-5564-17B
XPR-5564
XPR-5564
batteries only
CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV1 GRPS E-G T135°C
CLASS I ZONE 0 AEx ia IIC T3 Ga
I M1 Ex ia op is I Ma
II 1 G Ex ia op is IIC T3 Ga
Ex ia op is I Ma
Ex ia op is IIC T3 Ga
DEMKO 17 ATEX 1927
IECEx UL 17.0082
-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell Alkaline
3.7V/Cell Li-ion
IP-67
Um: 10V