I
mportant for the Installer
Before automating the frame, check that
1)
it is in good condition, in compliance
with the Machinery Directive and with
EN 12604.
2) Check that the location where the
installation is located enables com-
pliance with operating temperature
limits specified for the device.
3) The safety of the final installation and
compliance with all prescribed Stan-
dards (EN 12453 - EN 12445) is the
responsibility of the person who assem-
bles the various parts to construct a
total closing.
4) Use safety devices capable of monitor-
ing the status of their connection to the
electrical control unit.
5) Once installation is finished, it is rec-
ommended that all necessary checks
be performed (appropriate program-
ming of the control panel and cor-
rect installation of safety devices) to
ensure that compliant installation has
been performed.
6) Fix the control unit to a wall, using the
relevant support which is fitted to the
casing, in such a way as to leave said
support facing downwards and insert
the fixing screws in the special holes.
7) The control unit does not have any
type of isolating device for the 230
Vac line. It is therefore the respon-
sibility of the installer to set up an
isolating device inside the system. It
is necessary to install an omnipolar
switch, surge category III. It must be
positioned to provide protection from
accidental closing, pursuant to point
5.2.9 of EN 12453.
12