8) Cables for power and connection to the
motor suitable for insertion in the pg9
cable glands provided must have an out-
side diameter between 4.5 and 7 mm.
The internal conductors wires must have
a nominal section of 0.75mm
way is not used, use H05RR-F cables.
Pay careful attention when fastening
the cables so that they are anchored in a
stable manner.
Furthermore, care is required when
drilling holes in the outside casing
where connecting and power supply
cables will pass, and when assem-
bling the cable glands, so that every-
thing is installed so as to maintain the
panel's IP protection characteristics.
9) The gear motor used to move the
frame must comply with the require-
ments of point 5.2.7 of EN 12453.
10) In compliance with 5.4.2 of EN 12453,
it is recommended to use gear motors
equipped with an electrical-mechani-
cal release device, so that the frame
can be moved manually in case of
necessity.
. If a race-
2
11) In compliance with 5.4.3. of EN
12453, use electrical-mechanical
release systems or similar devices
which stop the frame safely in the
end run position.
12) The various electrical components
external to the control unit must be
cabled in accordance with standard
EN 60204-1 as amended, and as set
forth in point 5.2.7 of EN 12453. The
power and connection cables must
be secured through the use of cable
glands supplied.
13) The assembly of a push button panel
13