TECHNICAL DATA

Mod.
Dehumidification capacity
Electric heater power
Air flow
Sound pressure
Tank capacity
Power supply (voltage - n°phase - frequency)
* Power consumption
* Current consumption
Refrigerant
Refrigerant charge
Dimensions
Net weight
Gross weight
=sound pressure measured in free field condition at a frontal distance of 3 metres.
*
=performance values in cold conditions, Tair = 32 °C, HR = 80%
OPERATIVE LIMITS- PROTECTION AGAINST FREEZING AND EXCESSES OF HEAT
The protection device avoids uncontrolled freezing of the refrigerating circuit, avoiding therefore irreparable
damage. In this way the device is protected from possible irreparable damage.
The protection intervenes automatically by switching off the dehumidifier when the room temperature goes
below +5°C.
The dehumidifier starts operating again automatically only when the room temperature reaches +12°C.
The over temperature protection intervenes at + 35°C
[l/24h]
[W]
-
max
3
[m
/h]
min
max
[dB (A)]
min
[l]
[1~ / V /Hz]
[W]
[A]
[kg]
Height (A)
[mm]
Width (B)
[mm]
Depth (C)
[mm]
[kg]
[kg]
DF12
DF12R
DF20
12
12
20
500
-
800
180
180
240
140
140
170
42
42
48
40
40
44
2,3
2,3
4
1~ / 230 / 50
250
750
370
1,4
3,7
2,2
R134a
R134a
R134a
0,19
0,19
0,21
505
505
586
250
250
300
240
240
300
14
14
18,5
15
15
20
DF20R
DF35
DF35R
20
35
35
-
1000
240
300
300
170
230
230
48
48
48
44
44
44
4
10
10
1170
680
1680
5,7
3,5
8,3
R134a
R407C
R407C
0,21
0,35
0,35
586
710
710
300
350
350
300
360
360
19
24,5
24,5
20
26,5
26,5
21