at www.3M.com/sls.
4. The 6007 and 60927 mercury vapor cartridges must be discarded within 50 hours of use against mercury vapor; or according to organic vapor,
chlorine, hydrogen sulfide or sulfur dioxide service life, or when odors of vapors or gases become noticeable, whichever occurs first. Mercury vapor
has no odor.
NIOSH Cautions and Limitations
The following restrictions may apply. See NIOSH approval label.
A – Not for use in atmospheres containing less than 19.5 percent oxygen.
B – Not for use in atmospheres immediately dangerous to life or health.
C – Do not exceed maximum use concentrations established by regulatory standards.
D – Air-line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or
higher quality.
E – Use only the pressure ranges and hose lengths specified in the User's Instructions.
G – If airflow is cut off, switch to filter and/or cartridge or canister and immediately exit to clean air.
H – Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and canisters are replaced before
breakthrough occurs.
J – Failure to properly use and maintain this product could result in injury or death.
K – The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against
formaldehyde.
L – Follow the manufacturer's User's Instructions for changing cartridges, canister and/or filters.
M – All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N – Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O – Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
S – Special or critical User's Instructions and/or specific use limitations apply. Refer to User's Instructions before donning.
S – Special or Critical User's Instructions
3M™ Organic Vapor Service Life Indicator Cartridges (6001i and 60921i) are equipped with a passive 3M™ End of Service Life Indicator (ESLI). The
indicator must be readily seen when wearing the respirator. If you cannot readily see the ESLI, use a mirror to observe the ESLI; rely on a co-worker
who can see the ESLI; or go to a clean area, remove the respirator and view the ESLI. Do not rely solely on the organic vapor ESLI unless your
employer has determined that it is appropriate for your workplace. See 6001i or 60921i User Instructions for more information, including Special
Instructions regarding the ESLI.
3M™ Mercury Vapor, Organic Vapor and Acid Gas Cartridges (6007 and 60927) must be discarded within 50 hours of use against mercury vapor.
3M™ Particulate Filter P95, Hydrogen Fluoride, with Nuisance Level Acid Gas Relief, 2076HF and 3M™ Particulate Filter P100, Hydrogen Fluoride,
with Nuisance Level Acid Gas Relief, 7093C are recommended for relief against nuisance levels of acid gases or organic vapors. Nuisance level refers
to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower. Do not use for respiratory
protection against acid gases or organic vapors, except hydrogen fluoride.
To assemble 3M™ Dual Airline Combination Breathing Tubes with 3M™ Cartridges/Filters, the facepiece inhalation valves must be removed.
If the facepiece is to be used in air purifying mode (without using the 3M™ Breathing Tubes, SA-1600 or SA-2600), the inhalation valves must be
replaced in the facepiece before use.
Cartridge and Filter Selection and Approvals
Before using any of these products, the user must read the specific use for, use limitations and warning information in the User Instructions and
product packaging or call 3M Technical Service at 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.
Do not exceed maximum use concentrations established by local regulatory agencies. Cartridges/filters are approved as assemblies for use with 3M™
Half Facepiece 6000 Series. For NIOSH approval, refer to approval label.
LIST OF PRODUCT
3M™ Half Facepiece Respirators
Number
****AAD
6100
07024
6200
07025
6300
07026
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
3M™ Probed Half Facepiece Respirator (for quantitative fit testing only), includes 2091 P100 filters
Number
****AAD
6100Q
6200Q
6300Q
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
3M™ Half Facepieces Respirator Assemblies (includes 2091 P100 filters)
Number
****AAD
6191
6291
6391
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
Description
Small
Medium
Large
Description
Probed Respirator Assembly (Small)
Probed Respirator Assembly (Medium)
Probed Respirator Assembly (Large)
Description
Particulate Respirator, P100 (Small)
Particulate Respirator, P100 (Medium)
Particulate Respirator, P100 (Large)
3