3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge replacement.
2
NOTE: Not NIOSH approved for use against methylbromide or radioiodine.
3M™ Filters, Adapters, Retainers
NOTE: Only 3M™ Filters approved under NIOSH 42 CFR 84 are to be used with the 3M™ Half Facepiece
6000 Series.
Number
****AAD
Description
501
07054
Filter Retainer for Filters 5N11 and 5P71
502
Filter Adapter for Filters 2000 Series and 7093/7093C
603
Filter Adapter for Filters 5N11, 5P71 with Filter Retainer 501
2071
Particulate Filter, P95
Particulate Filter, P95, hydrogen fluoride, with nuisance level
2076HF
acid gas relief
Particulate Filter, P95, 3M recommended ozone protection
2078
with nuisance level organic vapor/acid gas relief
2091
07000
Particulate Filter, P100
2291
Advanced Particulate Filter, P100
2096
Particulate Filter, P100, with nuisance level acid gas relief
Advanced Particulate Filter, P100, with nuisance level acid
2296
gas relief
Particulate Filter, P100, 3M recommended for ozone
2097
07184
protection
Advanced Particulate Filter, P100, 3M recommended for
2297
ozone protection
5N11
Particulate Filter, N95
5P71
07194
Particulate Filter, P95
7093
Particulate Filter, P100
Particulate Filter, P100, hydrogen fluoride with nuisance level
7093C
37173
organic vapor/acid gas relief
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
3M recommended for relief against nuisance levels of acid gases or organic vapors. Nuisance level refers to concentrations not exceeding OSHA
1
PEL or applicable government occupational exposure limits, whichever is lower. Do not use for respiratory protection against acid gases or organic
vapors.
3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower.
2
NOTE: Not NIOSH approved for use against ozone. 3M particulate filters must be immediately changed when an increase in breathing
resistance is noticed.
In Brazil, the 3M™ Filter 5935BR is approved as a NIOSH N95 filter and as a BMOL P3 filter. It can be used
with the filter adaptor 603 and the filter retainer 501 on the 3M™ Half Facepiece 6000 Series.
ASSEMBLY INSTRUCTIONS
NOTE: Make certain 3M™ Inhalation Port Gaskets 6895 are in place on the facepiece bayonet connectors before installing filters, cartridges or
breathing tubes.
3M™ Cartridge 6000 Series, Filter 7093 and Cartridge/Filter 7093C
1. Align cartridge notch with facepiece mark, as shown, and push together (Fig. 1).
2. Turn cartridge clockwise to stop (1/4 turn) (Fig. 2).
3M™ Filters 5N11 and 5P71
1. Place filter into 501 retainer so printed side of filter faces the cartridge (Fig. 3).
2. Press cartridge into filter retainer. It should snap securely into filter retainer. When correctly installed, filter should completely cover face of cartridge.
3. To replace filter, remove retainer by lifting on tab.
In Brazil, the 5935BR Filter is assembled following the same procedures as the 5N11 and 5P71.
3M™ Filters 2000 Series
1. Align opening of filter with filter attachment on facepiece.
2. Turn filter clockwise until it is firmly seated and cannot be further turned.
3. Repeat for second filter.
3M™ Filter Adapter 502 and Filter Attachment
1. Align adapter over cartridge. Engage front snap by squeezing front of cartridge and adapter together, placing thumbs of both hands over top of
adapter and fingers along bottom sides of cartridge (Fig. 4).
2. Engage back snap by squeezing back side of cartridge and adapter together using the same hand positions (Fig. 5). An audible click should be
heard as each snap is engaged.
3. Place filter onto the filter holder so that filter comes into even contact with gasket. Twist clockwise a quarter turn until it is firmly seated and filter
cannot be turned further. Repeat for second filter.
NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may
1
1
, with nuisance level organic vapor relief
2
, with nuisance level organic vapor relief
2
1
,
2
1
1
1
1
5