Adjust the angle of the device that also measures the temperature.
The face image detected on the screen will appear after switching on the access control and
temperature measurement device
In order to permit the recognition of the face and the further measure of temperature, tilt the device
so that the user can position his face parallel to it. The same tilt of the face and of the device is
indispensable to obtain the best recognition.
The exposed part of the face (not covered by clothing or other) must be arranged in front of in
the "temperature measuring zone" (the optimal distance to reduce measurement errors is 0.5
m). After having determined the best position for correct temperature detection, it is advised to
place an indication with the words "Temperature reading position" on the floor.
Wall mount installation
Drill holes in the wall according to the mounting bracket.
Undo the tamper-proof fixing screw at the bottom of the equipment with an Allen key, remove
the mounting panel and secure the panel to the housing as shown in the figure below.
Connect the device to the mounting panel from top to bottom.
Use the Allen key to fasten the screws on the bottom of the bracket. The maximum recommended
installation height for adults is 1.45 metres (distance from the ground of the top of the device).