Technical Characteristics - Whirlpool AGB 669/WP Manual De Instalación De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
Voltage
Frequenza
Total power
Boiler element power
Tank element power
Wash pump power
Water supply pressure
Water supply temperature
Water supply hardness
Rinse cycle water consumption
Boiler capacity
Tank capacity
Standard cycle duration with water supply at 50°C
Noise level
Protection rating
Net weight
Power cable type
Electrical Scheme – voltage regulation
400/3 Volt
R
S
Wash Pump
2

Technical characteristics

230/3 Volt
T
R
S
T
AGB672
AGB669
400V/3+N
V
230V/1
Hz
50
kW
6,75
kW
6
kW
3
kW
0,75
kPa
200-400
°C
50 – 60
°dF
7 – 12
l
3,5
l
9
l
28
s
60/120/180/C
dB(A)
67
IPX
4
kg
115
◄HAR►
H05VV-F
TRB
400/3 Volt
Boiler Resistance
AGB666
AGB664
AGB670
400V/3+N
400V/3+N
230V/1
230V/1
50
50
7,1
10,75
6
10
3
3
1,1
0,75
200-400
200-400
50 – 60
15 – 30
7 – 12
7 – 12
3,5
3,5
9
12
35
28
60/120/180/C
60/120/180/C
67
67
4
4
123
118
H05VV-F
H05VV-F
TRB
230/3 Volt
4

Publicidad

Tabla de contenido
loading