Whirlpool AGB 669/WP Manual De Instalación De Uso página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
SETTINGS
During the first startup, arrange for the setup or the adjustment of the functions/parameters indicated
hereafter:
POWER SUPPLY : 200 – 250 VAC.
POWER CONSUMED : 4 VA
OPERATIONAL TEMPERATURE: 0 / 60 °C
OPERATIONAL HUMIDITY: max 90 % without condensation
NORMS: The control unit is designed and manufactured in observance of the
European norms in vigor regarding electrical safety and electromagnetic compatibility.
Particularly the following:
EN 61000-6-3 : Emissions for residential and commercial environments
EN 61000-6-2 : Immunity for industrial environments
EN 61000-4-11 : Immunity to supply micro-interruptions
EN 60335-1 : Low voltage safety directive
ZERO CROSSING : The relay which powers the tank's electrical resistance is equipped with the " zero crossing "
function which synchronizes the switching of this relay, both in closing and in opening, with the voltage supply's
passing to zero, both for 50 Hz and 60 Hz frequencies. In this manner, use of the relay's contacts is significantly
reduced.
Clamp
Connection for top-loading models
1 – 2
Control Unit Power Supply, 230 VAC
3 – 4
Boiler temperature sensor
5 – 6
Tank temperature sensor
10
Break-tank pressostat
11
Reserve input
12
Micro hood
13
Tank pressostat, closed over level
14
Common inputs
15
Boiler resistance remote control switch coil
16
Tank resistance, max. 10 Amp.
17
-
18
-
18 B.TANK
Rinse pump (machine type 4)
19
Wash pump ( max. 1 HP )
20
Rinse electrovalve + pressure increase pump
21
Drain pump ( max. 0.75 HP ) Optional
22
Output power supplies, 230 VAC phase
Parameter
Description
P0
Drain cycle time
P1
Boiler temperature
P2
Tank temperature
P3
Rinse duration
P4
Boiler stop option
7
6
TRONIC MODEL SETTINGS ( Installer )
Range
Preset
1-5'
1
60-95°C
82°C
40-65°C
55°C
10-40''
13"
YES/NO
0 NO

Publicidad

Tabla de contenido
loading

Tabla de contenido