TROUBLESHOOTING

Problem
Possible Cause
Motor will not run.
1. Fuse is blown or circuit breaker tripped.
2. Power cord not plugged in.
Motor runs hot
1. Voltage is too low.
and overload
2. Impeller not moving freely
kicks off or motor
does not run and
only hums
Motor runs but no
1. Improper priming.
water is
delivered.* *
2. Clogged foot valve (For shallow well
Unplug pump,
then open
faucets and see if
water is flowing
3. Discharge valve closed
through system
4. Pipe size too small
5. Impeller is plugged
6. Pipes are frozen
Pump does not
1. Corroded pipes.
deliver water to
2. Piping is too small in size.
full capacity.
3. Pump not being supplied with enough water.
4. Low voltage
8
application).
Corrective Action
1. DISCONNECT POWER; Replace fuse or
reset circuit breaker.
2. Plug into 115 Volt grounded outlet.
1. Check voltage being supplied to pump.
2. Unscrew 8 screws on housing and
Cleaned impeller. (Refer to Figure 7)
If needed call 1-844-242-2475 for further
help.
1. Re-prime according to instructions. (Refer
to Figure 2)
2. Stop pump, shut off water, check and
clean foot valve, replace with a new one if
necessary. (Refer to Figure 1)
3. Open valve.
4. Re-pipe using pipe of the same size as
suction and discharge ports on pump.
5. Unscrew 8 screws on housing and
Cleaned impeller. (Refer to Figure 7)
If needed call 1-844-242-2475 for further
help.
6. Thaw pipes.
1. Replace with plastic or new steel pipe.
2. Re-pipe using pipe the same size as
suction and discharge ports on pump
3. Enlarge inlet pipe; check well pump
system.
4. Make sure outlet voltage is at 115 Volts.
Figure 7
For Professional Technical Support call 1-844-242-2475