5 . Service

a) Have your power tool serviced by a qualified
repair person using only identical replace­
ment parts. This will ensure that the safety of
the power tool is maintained .
Device­specific safety instructions for
hammer drills
Wear hearing protection. Exposure
to loud noise can lead to hearing loss .
Use the additional handle supplied with the
appliance. Loss of control can lead to injuries .
Hold the appliance by the insulated handles
when you are carrying out work during which
the deployed tool may come into contact with
concealed power cables or its own power
cable. Contact with a live wire may electrify
exposed metal parts of the power tool and
could give the operator an electric shock .
Wear a dust mask.
WARNING! TOXIC DUST!
Working with the tool can produce harmful/
toxic dusts which represent a health hazard
for the person operating the appliance and
for anyone else in the vicinity .
CAUTION, POWER CABLES! DANGER!
Ensure that you are not likely to hit power, gas
or water supply lines when you are working
with the power tool . If necessary, check with
a service line detector before you start to cut
or drill into a surface .
Residual risks!
Even if you operate this power tool properly, there
will still be residual risks . The following risks can
occur in relation to the power tool's design and
structure:
1 . Lung damage if no suitable dust protection mask
is worn .
2 . Hearing damage, if no suitable hearing protec-
tion is worn .
PBH 800 A1
3 . Damage to health caused by hand-arm vibra-
tions if the appliance is used for extended peri-
ods or is not properly used and maintained .
WARNING!
The power tool creates an electromagnetic
field during operation . This field can, in cer-
tain circumstances, impair active or passive
medical implants . To reduce the risk of fatal
injuries, we recommend that people with
medical implants consult their doctor and the
manufacturer of the medical implant before
operating this machine .
Original accessories/auxiliary
equipment
Only use the accessories and additional
equipment which are specified in the operating
instructions and are compatible with the
appliance.

Operation

Additional handle

NOTE
For safety reasons, you should only use this
appliance with the additional handle
attached .
The gripping position of the additional handle
can be varied .
Turn the wing screw
the additional handle
little way .
Turn the additional handle
position .
Now, slide the locking positions on the addi-
tional handle
over the two locking pins on
the spindle of the appliance .
Retighten the wing screw
turning it in a clockwise direction .
anticlockwise and pull
off the appliance a
to the desired
afterwards by