24
UK
WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check the good functioning of the safety devices.
Any repair must be carried out by specialised personnel using original and certified materials.
The product must not be used by children and persons with reduces physical, sensorial or mental capacities, or
without experience and knowledge.
Do no access the control unit for adjustments and/or maintenances.
WARNING: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow this instruction to safeguard persons.
Keep this instruction manual.
1 - ELECTRICAL CONNECTIONS
Set up the electric system as shown in fig. 1 referring to the electric system regulations and other
national
regulations
service connections (photocells, sensitive edge, control units etc.).
The main components of the automated device are:
À Flashing light: 0.75 mm² 2-core (2x0,75) cable.
Á Antenna: screened coaxial cable.
 Key selector: 0,5 mm² 3-core (3x0,5) cable.
à Photocell receiver: 0,5 mm² 4-core (4x0,5) cable.
Ä Photocell transmitter: 0,5 mm² 2-core (2x0,5) cable.
Å Omnipolar magnetothermal differential switch with min. contact opening of 3 mm.
220-230Vac 50-60Hz power line to the device: 1,5 mm² min. 3-core (3x1,5) cable (adhere to the regulations
in force).
Æ Case for electronic control unit: 3x1,5 mm² cable.
Ç 230Vac operator:
Power supply: 1,5 mm² 4-core cable:
Grey = motor common; Brown = opening; Black = closing; Yellow/green = earth
È 8K2 sensitive edge: 0,5 mm² 2-core (2x0,5) cable.
Electronic lock: 1,5 mm² 2-core (2x1,5) cable.
0
Mechanical stops in opening and closing.
in
force.
Keeps
the
[ ]
mains
power
connection
TOP EVO
clearly
separated
from